Skip to content

CapsoCam Plus SV-3

by CapsoVision, Inc.

CapsoCam Plus SV-3 (2795) is a video capsule endoscopy system capsule (FDA Class II; FDA product code NEZ, System, Imaging, Gastrointestinal, Wireless, Capsule) made by CapsoVision, Inc., cleared under FDA 510(k) K192662 on 14 Feb 2020 (2 earlier submissions) and listed in FDA GUDID since 17 Jul 2018 (UDI-DI 00867770000209), active as of 22 Oct 2026. 3 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

3 closed

Documents

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK192662 Date14 Feb 2020DecidedStatusActive
United StatesGUDID listing Number00867770000209 UDI-DI Date17 Jul 2018ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
Small Bowel Capsule Endoscope
MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K192662 decided 14 Feb 2020 Active· +2 more in the status table
  • FDA GUDID UDI-DI 00867770000209 listed 17 Jul 2018 Listed

Recalls

3 recalls · FDA

    • Terminated Z-2536-2020 FDA Class II initiated 26 Feb 2020

    Ingestible video capsule system has capsule with incorrect capture mode which will not record data when the capsule is ingested by patients. If used, there is a risk of delay of diagnosis and the patient may need to repeat the exam.

    • Terminated Z-1827-2020 FDA Class II initiated 18 Oct 2019

    Capsule Endoscopy System: a defect present in the capsule window may be stressed through the production process and in the final package, which could cause the housing of the capsule to crack and leak when ingested. Fluid from the patient could leak in to the capsule, which may damage components inside the capsule and the patient data may not be retrieved; the patient may need to repeat the exam.

    • Terminated Z-2073-2020 FDA Class II initiated 3 Jul 2019

    Possible mis-labeling of the device with incorrect serial number labels which may result in a patient's misdiagnosis.

Timeline

7 dated events

  1. Cleared FDA 510(k) K161773
  2. Listed FDA GUDID 00867770000209
  3. Cleared FDA 510(k) K183192
  4. Recall initiated FDA recalls Z-2073-2020
  5. Recall initiated FDA recalls Z-1827-2020
  6. Cleared FDA 510(k) K192662
  7. Recall initiated FDA recalls Z-2536-2020

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
CapsoCam Plus
Generic name
Video capsule endoscopy system capsule
Model / Ref / Catalog
SV-3, 2795
Primary DI / UDI-DI
00867770000209
FDA product code
NEZ
GMDN term
Video capsule endoscopy system capsule
Device class
Class II
Regulation number
876.1300
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe

Other devices from CapsoVision, Inc.

  • CapsoCloud 3

    Class II
  • CapsoView 4

    Class II
  • CE Deliver DLV

    Class II
  • CapsoView (CVV)

    Class II

See all devices from CapsoVision, Inc. →

Properties

  • Single use
  • Prescription use
  • Lot / batch number
  • Serial number
  • Expiration date
  • Manufacturing date