Skip to content

Captiflex M00562400

by Boston Scientific

Ref M00562400

Captiflex M00562400 is an endoscopic electrosurgical handpiece/electrode (EU MDR Class IIb; FDA Class II; FDA product code FDI, Snare, Flexible) made by Boston Scientific, registered in EUDAMED on 31 Oct 2025 (Basic UDI-DI 01915060000000000000049MW) and listed in FDA GUDID since 24 Sep 2016 (UDI-DI 08714729747932), active as of 23 Oct 2026. 3 FDA recalls are linked to it.

Active European Union. Also listed in GUDID (US).

CE MDR

Valid until

No date given

EUDAMED holds no validity date

FDA recalls

3 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number01915060000000000000049MW Basic UDI-DI 08714729747932UDI-DIDate31 Oct 2025RegisteredStatusActive
United StatesGUDID listing GUDID Number08714729747932 UDI-DI Date24 Sep 2016ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
Single-Use Polypectomy Snare
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • EUDAMED Basic UDI-DI 01915060000000000000049MW registered 31 Oct 2025 Active
  • FDA GUDID UDI-DI 08714729747932 listed 24 Sep 2016 Listed

Recalls

3 recalls · 3 ongoing · FDA

    • Ongoing Z-1168-2021 FDA Class II initiated 19 Jan 2021 UDI-DI 08714729747932 listed

    Packaging Incomplete Seal. Users noted an incomplete pouch seal prior to using the device in a patient.

  • 2 recalls, same reason

    • Ongoing Z-2764-2020 FDA Class II initiated 6 Jul 2020 catalog no. M00562400 listed
    • Ongoing Z-2765-2020 FDA Class II initiated 6 Jul 2020 catalog no. M00562400 listed

    BSC has noted a potential inability to cut and remove polyps for these lots/batches. potential consequences related to the snares not performing as intended would be a prolonged procedure duration, tissue damage and/or self-limited bleeding. The most severe potential injury would include immediate or delayed hemorrhage and/or perforation requiring intervention up to and including open surgery; the likelihood of these severe injuries occurring is remote and, to date, have not been reported as a complaint. The potential inability to cut may also lead to inadequate removal of target tissue.

A catalog-number match means the recall lists this device's catalog or model number; the software version and lot are not checked.

Timeline

5 dated events

  1. Listed FDA GUDID 08714729747932
  2. Recall initiated FDA recalls Z-2764-2020
  3. Recall initiated FDA recalls Z-2765-2020
  4. Recall initiated FDA recalls Z-1168-2021
  5. Registered EUDAMED 01915060000000000000049MW

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States GUDID listing Listed

Specification

EUDAMED · GUDID

Trade name
Captiflex™ EUDAMED
Captiflex GUDID
Generic name
Endoscopic electrosurgical handpiece/electrode, monopolar, single-use
Device name
Captiflex Single-Use Polypectomy Snare
Model / reference
M00562400
Primary DI / UDI-DI
08714729747932
Basic UDI-DI
01915060000000000000049MW
FDA product code
FDI
EMDN code
G03030102 Polypectomy snares, non-revolving
GMDN term
Endoscopic electrosurgical handpiece/electrode, monopolar, single-use
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
876.4300
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under POLYPECTOMY SNARES, NON-REVOLVING.

Other devices from Boston Scientific

See all devices from Boston Scientific →

Properties

  • Supplied sterile
  • Single use
  • Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction)
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (19, all answered No)