# Captiflex M00562400

> Active: European Union. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/captiflex-m00562400>
- Manufacturer: [Boston Scientific](https://devicerts.com/manufacturers/boston-scientific) (United States)
- Name in the registry: CAPTIFLEX M00562400
- Device class: Class IIb (EU MDR); Class II (US FDA)
- FDA product code: FDI
- EMDN: G03030102 POLYPECTOMY SNARES, NON-REVOLVING
- GMDN: Endoscopic electrosurgical handpiece/electrode, monopolar, single-use (58039)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 01915060000000000000049MW · UDI-DI 08714729747932 · registered 2025-10-31 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 08714729747932 · listed 2016-09-24 · status: Listed (GUDID: in commercial distribution)

## Recalls

- Z-1168-2021 · Class II · ongoing · initiated 2021-01-19: Packaging Incomplete Seal. Users noted an incomplete pouch seal prior to using the device in a patient.
- Z-2764-2020 · Class II · ongoing · initiated 2020-07-06 · the recall lists this device's catalog number (version and lot not checked): BSC has noted a potential inability to cut and remove polyps for these lots/batches. potential consequences related to the snares not performing as intended would be a prolonged procedure duration, tissue damage and/or self-limited bleeding. The most severe potential injury would include immediate or delayed hemorrhage and/or perforation requiring intervention up to and including open surgery; the likelihood of these severe injuries occurring is remote and, to date, have not been reported as a complaint. The potential inability to cut may also lead to inadequate removal of target tissue.
- Z-2765-2020 · Class II · ongoing · initiated 2020-07-06 · the recall lists this device's catalog number (version and lot not checked): BSC has noted a potential inability to cut and remove polyps for these lots/batches. potential consequences related to the snares not performing as intended would be a prolonged procedure duration, tissue damage and/or self-limited bleeding. The most severe potential injury would include immediate or delayed hemorrhage and/or perforation requiring intervention up to and including open surgery; the likelihood of these severe injuries occurring is remote and, to date, have not been reported as a complaint. The potential inability to cut may also lead to inadequate removal of target tissue.

## Identity

- Trade name: CAPTIFLEX™ [EUDAMED]; CAPTIFLEX [FDA GUDID (AccessGUDID)]
- Generic name: Endoscopic electrosurgical handpiece/electrode, monopolar, single-use [FDA GUDID (AccessGUDID)]
- Device name: Captiflex Single-Use Polypectomy Snare [EUDAMED]
- Model / reference: M00562400 [EUDAMED, FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 08714729747932 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 01915060000000000000049MW [EUDAMED]
- FDA product code: FDI [FDA GUDID (AccessGUDID)]
- EMDN code: G03030102 [EUDAMED]
- GMDN term: Endoscopic electrosurgical handpiece/electrode, monopolar, single-use (58039) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class IIb [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 876.4300 [FDA GUDID (AccessGUDID)]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: Netherlands [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Supplied sterile: Yes [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: Yes [FDA GUDID (AccessGUDID)]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): Yes [EUDAMED]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Expiration date: Yes [FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Captiflex M00562400, Boston Scientific. deviCERTS medical device catalogue. https://devicerts.com/devices/captiflex-m00562400 (data as of 2026-11-29).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-23
- Statuses computed as of: 2026-11-29
- JSON: <https://devicerts.com/devices/captiflex-m00562400.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/captiflex-m00562400
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.