# Cardio-Wrap

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/cardio-wrap-dxz>
- Manufacturer: [MAST Biosurgery USA, Inc.](https://devicerts.com/manufacturers/mast-biosurgery-usa-inc) (FDA registration: United States)
- Name in the registry: CARDIO-WRAP
- Device class: Class II (US FDA)
- FDA product code: DXZ

## Overview

*AI-generated summary, 2026-10-01. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The Cardio-Wrap Bioresorbable Sheet is a Patch, Pledget, and Intracardiac Device composed of a 70:30 Poly(L-lactide-co-D,L-lactide) copolymer. It functions as a bioresorbable barrier designed to support pericardial defect coverage and facilitate postsurgical healing in cardiothoracic procedures. The material is engineered to degrade over time, reducing the need for long-term foreign-body presence.

This device is supplied sterile and intended for single-use in cardiac surgery settings. It is classified as a Class II medical device under FDA regulations (K090637, 510(k) clearance) and is available in a standard size of 100 x 130 x 0.05mm. Storage requires protection from moisture and extreme temperatures. Its primary indication, as referenced in submissions, is pericardial defect coverage, though clinical use is governed by surgical discretion.

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K090637 · decision 2010-01-07 · decision SESU · status: Active

## Recalls

No recall on record.

## Identifiers

- 510(k) Number: K090637 [FDA 510(k)]
- FDA product code: DXZ [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 870.3470 [FDA 510(k)]
- Advisory committee: Cardiovascular [FDA 510(k)]
- FDA decision: SESU [FDA 510(k)]

## Source and citation

- Cite as: Cardio-Wrap, MAST Biosurgery USA, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/cardio-wrap-dxz (data as of 2026-11-19).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/)
- Registry records last synced: 2026-11-08
- Statuses computed as of: 2026-11-19
- JSON: <https://devicerts.com/devices/cardio-wrap-dxz.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/cardio-wrap-dxz
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.