Cardiosave Hybrid Intra-Aortic Balloon Pump
by Cardiac Assist, Maquet Cardiovascular, LLC
510(k) K112372
Active
Valid until
No expiry
FDA recalls
26 ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK112372 | Date15 Sep 2011 | StatusActive |
Recalls
-
- Ongoing Z-1587-2026
The Battery Charging Station is an optional dual-bay charger used to charge the Cardiosave IABP Lithium- Ion batteries when they are not being used to operate the IABP. Getinge has identified that a protruding screw in the left battery bay limits full insertion of certain batteries and prevents proper charging. The right bay of the Battery Charging Station is not affected by this issue.
-
- Ongoing Z-0916-2026
The IFU addendum revises the Preventative Maintenance schedule to align with the update introduced in the Service Manual as of June 2023.
-
- Ongoing Z-0931-2026
- Ongoing Z-0932-2026
The IFU addendum updates the Vibration and Shock Table to reference the correct standards.
-
- Ongoing Z-1907-2023
The digital IFUs provided with the Cardiosave IABP during the software update to version D.00 incorrectly annotated compliance to standard 60601-1-12:2014 within the updated IFU.
-
- Ongoing Z-1462-2023
The power cord supplied (Type J plug end) for the Cardiosave Hybrid IABP to Brazil is incompatible with the Brazilian Type N power receptacle.
-
- Ongoing Z-1279-2023
- Ongoing Z-1276-2023
- Ongoing Z-1278-2023
- Ongoing Z-1277-2023
There is an issue related to the Safety Disk not meeting a performance requirement that may impact Intra-Aortic Balloon catheter (IAB) displacement volume. This potential failure of an impacted Safety Disk may lead to slightly reduced IAB inflation during therapy or a reduction in the degree of augmentation provided to the patient during therapy.
-
- Ongoing Z-1146-2023
- Ongoing Z-1145-2023
An unexpected shutdown of the IABP may occur due to a failure of the connection between the Coiled Cord cable and the Cable Assembly backplane to the Coiled Cord cable which provides the communication between the display head and base unit.
-
- Ongoing Z-1230-2023
- Ongoing Z-1229-2023
There have been reported failures of the high pressure helium regulator, which may cause a helium leak in the Cardiosave Hospital Cart. In instance of helium regulator failure, a Pump Console s internal reservoir of helium will not be replenished when docked into an impacted Hospital Cart. This may result in an insufficient amount of helium within the internal reservoir.
-
- Ongoing Z-0336-2022
- Ongoing Z-0337-2022
Firm is initiating a correction due to the possibility of fluid ingress. Fluid entering the device may short various electronic components thus leading to system shutdown, which could result in unsafe hemodynamic instability.
-
- Ongoing Z-0091-2022
A Cardiosave Lithium-Ion Battery Pack used during protocol testing failed to meet the minimum runtime requirement per Getinge internal Product Specification. These nonconforming batteries were inadvertently released to customers.
-
- Ongoing Z-2615-2021
The Cardiosave IABP may unexpectedly shut down when the device is running on AC power, only one battery is installed in the IABP, and the battery is physically removed while the battery is being charged. This occurs during a very specific set of conditions.
-
- Ongoing Z-0075-2022
The Helium Indicator on the Cardiosave display may over represent the amount of helium in unit in the presence of Electromagnetic Interference.
-
- Ongoing Z-1507-2021
- Ongoing Z-1506-2021
There are cybersecurity vulnerabilities in a widely used low-level TCP/IP software library that may result in a loss of communication to the Hospital Information System/Clinical Information System (HIS/CIS).
-
- Ongoing Z-1942-2019
- Ongoing Z-1940-2019
If battery maintenance is not performed appropriately, the battery may provide less than the minimum run time of operating power. Revised labeling and training are being provided.
-
- Ongoing Z-1941-2019
If battery maintenance is not performed appropriately, the battery may provide less than the minimum run time of operating power. Revised labeling and training are being offered.
-
- Ongoing Z-1939-2019
Battery short-run times and unanticipated stoppage may be due to user not performing battery maintenance and handling as needed. Inadequate labeling is being targeted for this recall, and design updates will be handled in a subsequent recall.
-
- Ongoing Z-1928-2018
Ingress of fluids into the device can affect various electronic circuit boards which would prevent initiation or continuation of therapy.
-
- Terminated Z-1386-2017
Maquet has received 3 confirmed complaints related to the Li-lon Battery used with the Maquet CARDIOSAVE Hybrid IABP and Maquet CARDIOSAVE Rescue IABP of the battery venting after being accidentally dropped.
-
- Terminated Z-1248-2016
Maquet has recieved information that in some Cardiosave IABPS, the scroll compressor did not meet the specifications for output pressure or vacuum at specific flow rates.
-
- Terminated Z-1140-2015
Power supply malfunction complaints related to suboptimal thermal management.
-
- Terminated Z-1062-2015
Ferrule Cap was not removed on some fiber-optic Sensation and Sensation Plus IABC demonstration units. If fiber-optic connector is inserted into the Maquet CS300 or CARDIOSAVE IABP, cap will prevent connection of unit and may become dislodged and remain in IABPs fiber-optic receptacle.
-
- Terminated Z-0662-2013
In the Cardiosave Intra-aortic Balloon Pump, there is a possibility that the coiled cord assembly, a prominent connector cord between the Cardiosave IABP housing and the dual display head which secured atop the IABP may fail as a result of mishandling.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DSP
- Device Class
- Class II
- Regulation
- 21 CFR Part 870.3535
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent