Carescape Central Station MAI800
by Ge Medical Systems Information Technologies, Inc. United States GUDID
Product code DQK
Regulatory status
Recall ongoing. 5 ongoing FDA recalls. See recalls
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00195278343512 | Date11 Feb 2026 | StatusIn distribution |
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not known
- Not covered
United States — GUDID listing Listed
Recalls
-
- Ongoing Z-3143-2026
Device may not resume patient monitoring for at least 3 minutes following system restart. Issue can lead to potential delay in recognition of clinically significant events.
-
- Ongoing Z-0213-2026
- Ongoing Z-0214-2026
Carescape Central Station (CSCS), software version V3.0.5, can cause the system to enter a continuous reboot cycle. If this occurs, a loss of central monitoring of connected patients could result. This issue occurs only when the number of central stations connected to the network is 118, 119 or 120.
-
- Ongoing Z-1265-2022
The CARESAPE Central Station (CSCS) V2 can shut down due to a potential power supply component failure. This can lead to loss of patient monitoring at the central station.
-
- Ongoing Z-0808-2022
If the CARESCAPE Central Station v2.0 is used with an unapproved keyboard, the audio can be muted resulting in loss of audible alarms.
-
- Terminated Z-0487-2018
CARESCAPE Central Station (CSCS) software version 2.0.2 units may experience unexpected NO COMM (No Communication) and network communication issues after boot-up or system restart.
Specification
- Trade Name
- Carescape Central Station
- Generic Name
- Centralized patient monitor
- Model / Ref / Catalog
- MAI800, 5867474-04
- Primary DI / UDI-DI
- 00195278343512
- 510(k) Number
- FDA Product Code
- DQK, DSI, DXH
- GMDN Term
- Centralized patient monitor
- Device Class
- Class II
- Regulation Number
- 870.1425, 870.1025, 870.2920
- Commercial Distribution
- In Commercial Distribution
- MRI Safety
- MR Unsafe
Other devices from Ge Medical Systems Information Technologies, Inc.
See all devices from Ge Medical Systems Information Technologies, Inc. →
Properties & raw data
Show properties, registry sources and raw records
Other properties (11)
- Sterile: No
- Single Use: No
- Implantable: No
- Contains Latex: No
- Over-the-Counter: No
- Convenience Kit: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Lot / Batch Number: No
- Expiration Date: No
Sources (1)
- FDA UDI b6c49b97-0d9f-462e-926b-63b35c10a658