Skip to content

CASCADIA™ Interbody System 6101-90167

by VB Spine LLC

Ref 6101-90167Model 08858251004174T2

CASCADIA Interbody System 6101-90167 is an orthopaedic inorganic implant inserter/extractor (EU MDR Class I; FDA Class II) made by VB Spine LLC, registered in EUDAMED on 29 Aug 2026 (Basic UDI-DI 08858251004174T2) and listed in FDA GUDID since 2 Sep 2016 (UDI-DI 10888857270107), active as of 23 Oct 2026.

Active European Union. Also listed in GUDID (US).

CE MDR

Valid until

No date given

EUDAMED holds no validity date

FDA recalls

Not checked

No FDA submission to match recalls against

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number08858251004174T2 Basic UDI-DI 10888857270107UDI-DIDate29 Aug 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number10888857270107 UDI-DI Date2 Sep 2016ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
6101-90167
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • EUDAMED Basic UDI-DI 08858251004174T2 registered 29 Aug 2026 Active
  • FDA GUDID UDI-DI 10888857270107 listed 2 Sep 2016 Listed

Timeline

2 dated events

  1. Listed FDA GUDID 10888857270107
  2. Registered EUDAMED 08858251004174T2

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States GUDID listing Listed

Specification

EUDAMED · GUDID

Trade name
CASCADIA™ Interbody System
Generic name
Orthopaedic inorganic implant inserter/extractor, reusable
Device name
Cascadia: Inserter
Model / Ref / Catalog
6101-90167, 08858251004174T2
Primary DI / UDI-DI
10888857270107
Basic UDI-DI
08858251004174T2
Direct marketing DI
10888857270107
FDA product code
MAX, OVD, ODP
EMDN code
L091001 Instruments for insertion and extraction of materials for osteosynthesis, reusable
GMDN term
Orthopaedic inorganic implant inserter/extractor, reusable
Device class
Class I EUDAMED
Class II GUDID
Regulation number
888.3080
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Size
Width — 10 Millimeter

Truth per registry

2 sources · 3 fields differ

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class II
Supplied sterileEUDAMED
No
GUDID
Yes
Sterilise before useEUDAMED
Yes
GUDID
No

Registry differences

EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:

  • Supplied sterile UDI-DI 10888857270107: EUDAMED states No, FDA GUDID states Yes.
  • Sterilise before use UDI-DI 10888857270107: EUDAMED states Yes, FDA GUDID states No.

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under INSTRUMENTS FOR INSERTION AND EXTRACTION OF MATERIALS FOR OSTEOSYNTHESIS, REUSABLE.

Other devices from VB Spine LLC

See all devices from VB Spine LLC →

Properties

  • Supplied sterile NoEUDAMEDYesGUDID
  • Sterilise before use YesEUDAMEDNoGUDID
  • Reusable
  • Prescription use
  • Lot / batch number
Other properties (20, all answered No)