PTA Balloon Dilatation Catheter
510(k) K902454
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK902454 | Date30 Aug 1990 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Full name
- Cathscanner(R) PTA Balloon Dilatation Catheter
- 510(k) Number
- FDA Product Code
- LIT
- Device Class
- Class II
- Regulation
- 21 CFR Part 870.1250
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 19 Sep 2026
The PTA Balloon Dilatation Catheter is a peripheral angioplasty device designed for transluminal dilation of arterial obstructions. It is classified as a catheter under the nomenclature for vascular interventions, intended to mechanically widen narrowed or blocked blood vessels in peripheral arteries through controlled balloon inflation.
This device is supplied as a single-use, non-sterile catheter and is regulated under FDA 510(k) clearance (K902454) with a classification of Class II. It is intended for use in interventional cardiology settings and is compatible with standard 0.018-inch and 0.035-inch guidewires, available in both Rapid Exchange (RX) and Over-the-Wire (OTW) configurations. No MRI safety information or reusable specifications are provided.
Other devices from Endosonics Corp.
Questions
AI-generated answers, 19 Sep 2026
What is the primary use of the CATHSCANNER® PTA Balloon Dilatation Catheter in clinical practice?
The CATHSCANNER® PTA Balloon Dilatation Catheter is specifically designed for peripheral angioplasty, meaning it is used to mechanically widen narrowed or blocked blood vessels in peripheral arteries. This is achieved through controlled inflation of the balloon within the catheter, helping restore blood flow in obstructed arterial pathways.
Is the CATHSCANNER® PTA Balloon Dilatation Catheter intended for reuse, or is it single-use only?
The device is explicitly labeled as single-use only, meaning it is not meant to be reused after a single procedure. This classification aligns with standard medical device safety protocols to prevent contamination and ensure patient safety.
What guidewire compatibility does the CATHSCANNER® PTA Balloon Dilatation Catheter support, and how does this affect its use?
The catheter is compatible with both 0.018-inch and 0.035-inch guidewires, and it is available in Rapid Exchange (RX) and Over-the-Wire (OTW) configurations. This flexibility allows clinicians to choose the appropriate guidewire based on the procedural requirements, ensuring compatibility with existing interventional cardiology workflows.
How is the CATHSCANNER® PTA Balloon Dilatation Catheter supplied, and does it come pre-sterilized?
The device is supplied as non-sterile, meaning it requires sterilization by the healthcare facility prior to use. This is a standard practice for certain medical devices to allow hospitals to use their preferred sterilization methods, ensuring optimal cleanliness and safety for each procedure.
What regulatory pathway was followed for the FDA clearance of the CATHSCANNER® PTA Balloon Dilatation Catheter, and what does this imply for its use?
The device received FDA 510(k) clearance (K902454) under the Traditional 510(k) Review pathway, with a classification of Class II. This implies that the device was determined to be substantially equivalent to a legally marketed predicate device and is regulated under stricter controls than Class I but not as stringent as Class III. Clinically, this means it is considered safe and effective for its intended use in peripheral arterial dilation under interventional cardiology protocols.