Skip to content

PTA Balloon Dilatation Catheter

by Endosonics Corp.

510(k) K902454

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK902454 Date30 Aug 1990ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
Cathscanner(R) PTA Balloon Dilatation Catheter
510(k) Number
FDA Product Code
LIT
Device Class
Class II
Regulation
21 CFR Part 870.1250
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The PTA Balloon Dilatation Catheter is a peripheral angioplasty device designed for transluminal dilation of arterial obstructions. It is classified as a catheter under the nomenclature for vascular interventions, intended to mechanically widen narrowed or blocked blood vessels in peripheral arteries through controlled balloon inflation.

This device is supplied as a single-use, non-sterile catheter and is regulated under FDA 510(k) clearance (K902454) with a classification of Class II. It is intended for use in interventional cardiology settings and is compatible with standard 0.018-inch and 0.035-inch guidewires, available in both Rapid Exchange (RX) and Over-the-Wire (OTW) configurations. No MRI safety information or reusable specifications are provided.

Other devices from Endosonics Corp.

See all devices from Endosonics Corp. →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary use of the CATHSCANNER® PTA Balloon Dilatation Catheter in clinical practice?

    The CATHSCANNER® PTA Balloon Dilatation Catheter is specifically designed for peripheral angioplasty, meaning it is used to mechanically widen narrowed or blocked blood vessels in peripheral arteries. This is achieved through controlled inflation of the balloon within the catheter, helping restore blood flow in obstructed arterial pathways.

  • Is the CATHSCANNER® PTA Balloon Dilatation Catheter intended for reuse, or is it single-use only?

    The device is explicitly labeled as single-use only, meaning it is not meant to be reused after a single procedure. This classification aligns with standard medical device safety protocols to prevent contamination and ensure patient safety.

  • What guidewire compatibility does the CATHSCANNER® PTA Balloon Dilatation Catheter support, and how does this affect its use?

    The catheter is compatible with both 0.018-inch and 0.035-inch guidewires, and it is available in Rapid Exchange (RX) and Over-the-Wire (OTW) configurations. This flexibility allows clinicians to choose the appropriate guidewire based on the procedural requirements, ensuring compatibility with existing interventional cardiology workflows.

  • How is the CATHSCANNER® PTA Balloon Dilatation Catheter supplied, and does it come pre-sterilized?

    The device is supplied as non-sterile, meaning it requires sterilization by the healthcare facility prior to use. This is a standard practice for certain medical devices to allow hospitals to use their preferred sterilization methods, ensuring optimal cleanliness and safety for each procedure.

  • What regulatory pathway was followed for the FDA clearance of the CATHSCANNER® PTA Balloon Dilatation Catheter, and what does this imply for its use?

    The device received FDA 510(k) clearance (K902454) under the Traditional 510(k) Review pathway, with a classification of Class II. This implies that the device was determined to be substantially equivalent to a legally marketed predicate device and is regulated under stricter controls than Class I but not as stringent as Class III. Clinically, this means it is considered safe and effective for its intended use in peripheral arterial dilation under interventional cardiology protocols.