Polysafe Endocardial Pacing Lead
by Cardiac Control Systems, Inc.
510(k) K864601
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK864601 | Date6 Jan 1987 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Full name
- Ccs Polysafe(Tm) Endocardial Pacing Lead
- 510(k) Number
- FDA Product Code
- DTB
- Device Class
- Class III
- Regulation
- 21 CFR Part 870.3680
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
The Polysafe Endocardial Pacing Lead is a Permanent Pacemaker Electrode, designed for endocardial pacing applications. It delivers electrical stimulation to the heart’s endocardium, facilitating cardiac rhythm regulation in patients requiring chronic pacing support. Constructed with a durable, biocompatible design, it ensures reliable signal transmission while minimising tissue irritation or damage over prolonged use.
This lead is intended for use in cardiac electrophysiology procedures, typically implanted via venous access to position the electrode tip within the right ventricle or atrium. Supplied sterile and intended for single-use, it adheres to Class III regulatory standards under FDA 510(k) clearance (K864601) and is governed by regulation 870.3680. Storage requires adherence to manufacturer guidelines for sterile packaging integrity, and its design complies with MRI safety standards for Class C devices.
Other devices from Cardiac Control Systems, Inc.
Questions
AI-generated answers, 18 Sep 2026
What is the primary purpose of the CCS Polysafe™ Endocardial Pacing Lead, and how is it implanted in patients?
The CCS Polysafe™ Endocardial Pacing Lead is designed for endocardial pacing, delivering electrical stimulation directly to the heart’s inner lining (endocardium) to regulate cardiac rhythm in patients requiring chronic pacing support. It is typically implanted via venous access, positioning the electrode tip within the right ventricle or atrium to ensure reliable pacing over long-term use.
Is the CCS Polysafe™ Endocardial Pacing Lead intended for single-use or reusable applications, and how should it be stored?
The lead is sterile and intended for single-use only, as specified in its design. Storage must follow the manufacturer’s guidelines to maintain sterile packaging integrity, ensuring it remains uncontaminated until use.
Does this device comply with MRI safety standards, and if so, what class does it fall under?
Yes, the CCS Polysafe™ Endocardial Pacing Lead is designed to comply with MRI safety standards and is classified as a Class C device, allowing for controlled MRI imaging under specific conditions.
What regulatory pathway was followed for FDA clearance of this device, and which advisory committee reviewed it?
The device underwent a Traditional 510(k) review and was deemed Substantially Equivalent (SESE) to a predicate. It was reviewed by the Cardiovascular (CV) Advisory Committee and cleared under FDA 510(k) number K864601, governed by regulation 870.3680.