Skip to content

CD Horizon Spinal System

by Medtronic 3 variants

510(k) K211596

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Special NumberK211596 Date23 Jun 2021ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
OLO
Device class
Class II
Regulation
21 CFR Part 882.4560
Advisory committee
Neurology
FDA decision
SESE Substantially Equivalent

Overview

AI-generated summary, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The CD Horizon Spinal System is a spinal fixation device designed for posterior, non-cervical surgical applications. It includes rod-to-rod and screw-to-rod connectors, enabling modular construct assembly for spinal deformity correction, revision surgery, and multi-rod constructs. The system supports variable rod diameters and materials, facilitating construct extension without hardware removal. Its design is intended as an adjunct to spinal fusion procedures.

This system is supplied sterile and intended for single-use. It is regulated under FDA 510(k) clearance (K211596) as substantially equivalent to a predicate device, with a special review classification. Components include rods, hooks, screws, and connectors in various configurations, with no specific MRI safety restrictions noted. Storage and handling follow standard surgical instrument protocols, adhering to manufacturer guidelines for sterility and surgical application.

Other devices from Medtronic, Inc.

See all devices from Medtronic, Inc. →

Questions

AI-generated answers, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of spinal surgeries is the CD Horizon Spinal System designed to support, and how does its modularity benefit the surgeon?

    The CD Horizon Spinal System is specifically designed for posterior, non-cervical spinal surgeries, serving as an adjunct to spinal fusion procedures. Its modularity—through rod-to-rod and screw-to-rod connectors—allows surgeons to assemble customizable constructs for spinal deformity correction, revision surgeries, or multi-rod applications. This modularity enables construct extension without the need for hardware removal, reducing surgical time and potential complications while accommodating variable rod diameters and materials.

  • Is the CD Horizon Spinal System intended for reuse, or is it meant to be used once and then discarded?

    The CD Horizon Spinal System is explicitly intended for single-use only, as stated in the manufacturer’s instructions. This design ensures patient safety and sterility, aligning with standard surgical protocols for spinal fixation devices.

  • What types of components are included in the CD Horizon Spinal System, and can they be mixed and matched?

    The system includes rods, hooks, screws, and connectors in various configurations, allowing for modular assembly. While the components are designed to be compatible with one another, their specific mixing and matching should follow the manufacturer’s guidelines to ensure proper functionality and safety during spinal fixation procedures.

  • How should the CD Horizon Spinal System be stored to maintain its sterility and usability?

    The system is supplied sterile, so storage must adhere to standard surgical instrument protocols to preserve sterility. The manufacturer’s guidelines should be followed for proper handling, packaging, and environmental conditions to ensure the device remains uncontaminated until use.

  • Are there any restrictions on using the CD Horizon Spinal System with MRI scans after implantation?

    The CD Horizon Spinal System does not have specific MRI safety restrictions noted in its documentation. However, clinicians should always verify compatibility with their MRI equipment and follow the manufacturer’s instructions to ensure safe imaging post-implantation, as MRI safety can vary based on individual components and settings.