CEREBASE DA guide sheath
by Medos International SARL 4 variants
Ref GS9080SD
CEREBASE DA guide sheath (GS9080SD) is a vascular guide-catheter (EU MDD Class III; FDA Class II; FDA product code QJP, Catheter, Percutaneous, Neurovasculature) made by Medos International SARL, registered in EUDAMED on 3 Feb 2026 (Basic UDI-DI B-CHMF000014268000011XU), cleared under FDA 510(k) K192804 on 27 Feb 2020 and listed in FDA GUDID since 13 Apr 2020 (UDI-DI D-CHMF000014268000011XU), active as of 25 Oct 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
1 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-CHMF000014268000011XU D-CHMF000014268000011XU | Date3 Feb 2026 | StatusActive |
| United States | GUDID listing GUDID | NumberD-CHMF000014268000011XU | Date13 Apr 2020 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK192804 | Date27 Feb 2020 | StatusActive |
Official records
- EUDAMED public site B-CHMF000014268000011XU
- AccessGUDID record 10886704082316
- FDA 510(k) database K192804
From the FDA record
- Device description
- CEREBASE DA Guide Sheath Working Length: 80 cm ID: 0.090 in/2.29 mm Short Sheath Compatability: 8F
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI B-CHMF000014268000011XU registered 3 Feb 2026 Active
- FDA 510(k) K192804 decided 27 Feb 2020 Active
- FDA GUDID UDI-DI D-CHMF000014268000011XU listed 13 Apr 2020 Listed
Recalls
-
- Ongoing Z-1284-2024
Medos has received an increase in complaints for CEREBASE DA Guide Sheath with reports of fractures at the distal end, which may result in surgical procedural delay, vascular injury and in extreme rare occasions it may result in embolism.
Timeline
- Cleared FDA 510(k) K192804
- Listed FDA GUDID D-CHMF000014268000011XU
- Recall initiated FDA recalls Z-1284-2024
- Registered EUDAMED B-CHMF000014268000011XU
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- CEREBASE DA guide sheath EUDAMEDCerebase GUDID
- Generic name
- Vascular guide-catheter, single-use
- Model / Ref / Catalog
- GS9080SD
- Primary DI / UDI-DI
- D-CHMF000014268000011XU EUDAMED10886704082316 GUDID
- Basic UDI-DI
- B-CHMF000014268000011XU
- 510(k) Number
- FDA product code
- QJP
- EMDN code
- C010499 Angiography and hemodynamics devices - other
- GMDN term
- Vascular guide-catheter, single-use
- Device class
- Class III EUDAMEDClass II GUDID
- Regulation number
- 870.1250
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Belgium
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Primary DI / UDI-DI | D-CHMF000014268000011XU | 10886704082316 |
| Device class | Class III | Class II |
Manufacturer details
- EUDAMED SRN
- CH-MF-000014268
- Authorised representative
- DePuy Ireland UC IE-AR-000009328
Similar devices in this category
Other devices filed under ANGIOGRAPHY AND HEMODYNAMICS DEVICES - OTHER.
- NeuroSlider 01-000273 by Acandis GmbH
- IntraSight Plus 797417 by Philips Image Guided Therapy Corporation
- SyncVision Medical Image Processing System 400-0100.10 by VOLCANO CORPORATION
- McKesson Cardiology Hemo 13.2.1 by Change Healthcare Canada Company
- Spectrumedics SPM-3500 by Spectrumedics Medical Technology (Shanghai) Co., Ltd.
- IntraSight Mobile System 797415 by VOLCANO CORPORATION
- Change Healthcare Cardiology 15.0 by Change Healthcare Canada Company
- Shockwave IVL System with the Shockwave Javelin Peripheral IVL Catheter JVNPIVLF by Shockwave Medical Inc.
- NeuroSlider 01-000272 by Acandis GmbH
- GENOSS Inflator B40 GBI-B40V by Genoss