Identity
- Trade Name
- Chlorine Sentinel II FDA UDI
- Generic Name
- Haemodialysis system chlorine monitor FDA UDI
- Device Name
- Chlorine Sentinel II is a complete system that attaches to the drain of a hemodialysis water treatment system sample port. It detects dissolved combined chlorine in concentrations at or above 10 PPB by primary detection technology. It self-monitors for maintenance-required conditions and loss of electrical power. The Chlorine Sentinel II is self-testing. It uses chlorinated city water to automatically test the chlorine detecting functionality of the device once a day and records if the test passed, failed to detect chlorine, or didn’t rinse out after detecting chlorine. The device is designed to use as little water as possible. The sampling water is only used for the length of time that it takes for the chlorine test to be completed. The customer determines how frequently the test needs to be taken from every 5 minutes to every 20 minutes. The user also sets the start time and end time for each day of the week. The Chlorine Sentinel II has two combined chlorine concentration set points. The user can set a warning set-point at a value of 0.01 PPM to 0.09 PPM. Once the chlorine concentration exceeds this value, the device will alarm at 2-HZ to warn the user of chlorine present at that set-point. The second set-point is factory set at 0.10 PPM. A chlorine concentration equal to or above the 0.10 PPM set-point will activate the buzzers and the red chlorine alarm indicators at 5 HZ for as long as the condition exists. The buzzers can only be muted for 3 minutes (then automatically reset) for as long as the condition exists. The alarms can be by-passed. When by-passed the pulsing lights will turn solid and the buzzer will double click over 15 minutes. The front cover of the device has two screens. The screen of the chlorine monitor indicates the presence of combined chlorine when the value is not 0.000. The touch screen is used to enter user data and show the statuses of the device. FDA UDI
- Model / Reference
- NSS-CS-II-001 FDA UDI
- Description
- Chlorine Sentinel II is a complete system that attaches to the drain of a hemodialysis water treatment system sample port. It detects dissolved combined chlorine in concentrations at or above 10 PPB by primary detection technology. It self-monitors for maintenance-required conditions and loss of electrical power. The Chlorine Sentinel II is self-testing. It uses chlorinated city water to automatically test the chlorine detecting functionality of the device once a day and records if the test passed, failed to detect chlorine, or didn’t rinse out after detecting chlorine. The device is designed to use as little water as possible. The sampling water is only used for the length of time that it takes for the chlorine test to be completed. The customer determines how frequently the test needs to be taken from every 5 minutes to every 20 minutes. The user also sets the start time and end time for each day of the week. The Chlorine Sentinel II has two combined chlorine concentration set points. The user can set a warning set-point at a value of 0.01 PPM to 0.09 PPM. Once the chlorine concentration exceeds this value, the device will alarm at 2-HZ to warn the user of chlorine present at that set-point. The second set-point is factory set at 0.10 PPM. A chlorine concentration equal to or above the 0.10 PPM set-point will activate the buzzers and the red chlorine alarm indicators at 5 HZ for as long as the condition exists. The buzzers can only be muted for 3 minutes (then automatically reset) for as long as the condition exists. The alarms can be by-passed. When by-passed the pulsing lights will turn solid and the buzzer will double click over 15 minutes. The front cover of the device has two screens. The screen of the chlorine monitor indicates the presence of combined chlorine when the value is not 0.000. The touch screen is used to enter user data and show the statuses of the device. FDA UDI
Identifiers
- Primary DI / UDI-DI
- 00860006352165 FDA UDI
- FDA Product Code
- MSY FDA UDIPSX FDA UDI
- GMDN Term
- Haemodialysis system chlorine monitor FDA UDI
Classification
- Device Class
- Class II FDA UDI
- Regulation Number
- 876.5665 FDA UDI
- Commercial Distribution
- In Commercial Distribution FDA UDI
Clinical & Handling
Sterile
No
FDA UDI
Single Use
No
FDA UDI
Implantable
No
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
No
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
No
FDA UDI
Lot / Batch Number
Yes
FDA UDI
Serial Number
Yes
FDA UDI
Expiration Date
Yes
FDA UDI
Manufacturing Date
Yes
FDA UDI
Category: Haemodialysis system chlorine monitor
Chlorine Sentinel II by Nelson Environmental Technologies Inc — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Similar devices
Also classified as Haemodialysis system chlorine monitor.
- BMT Medizintechnik GmbH — BMT Medizintechnik GmbH · Class I
- BMT Medizintechnik GmbH — BMT Medizintechnik GmbH · Class I
- BMT Medizintechnik GmbH — BMT Medizintechnik GmbH · Class I
- BMT Medizintechnik GmbH — BMT Medizintechnik GmbH · Class I
- BMT Medizintechnik GmbH — BMT Medizintechnik GmbH · Class I
- BMT Medizintechnik GmbH — BMT Medizintechnik GmbH · Class I
- BMT Medizintechnik GmbH — BMT Medizintechnik GmbH · Class I
- BMT Medizintechnik GmbH — BMT Medizintechnik GmbH · Class I
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class II | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Nelson Environmental Technologies Inc
Sources (1)
- FDA UDI 4932995d-ab8e-4fb4-974a-5b846935d47f 33 fields · synced Jun 8, 2026