Skip to content

CINA

by Avicenna.AI

Ref ++B826CINA10RR

++B826CINA10RR is a medical device (EU MDD Class I; FDA Class II; FDA product code QAS, Radiological Computer-Assisted Triage And Notification Software) made by Avicenna.ai, registered in EUDAMED on 21 Nov 2022 (Basic UDI-DI B-B826CINA100), cleared under FDA 510(k) K200855 on 24 Jun 2020 and listed in FDA GUDID since 14 Dec 2020 (UDI-DI B826CINA100), active as of 22 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K200855

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-B826CINA100 Basic UDI-DI B826CINA100UDI-DIDate21 Nov 2022RegisteredStatusActive
United StatesGUDID listing GUDID NumberB826CINA100 UDI-DI Date14 Dec 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k) GUDID from GUDID NumberK200855 Date24 Jun 2020IssuedStatusActive

Official records

From the FDA record

Device description
CINA is a radiological computer-assisted triage and notification software device. The software system is based on algorithm-programmed components and is comprised of a standard off-the-shelf operating system and additional image processing applications. DICOM images are received, recorded and filtered before processing. The series are processed chronologically by running algorithms on each series to detect suspicious results of an intracranial hemorrhage (ICH) or a large vessel occlusion (LVO), then notifications on the flagged series are sent to the Worklist Application. The Worklist Application (on premise) displays the pop-up notifications of new studies with suspected findings when they come in, and provides both active and passive notifications. Active notifications are in the form of a small pop-up containing patient name, accession number and the type of suspected findings (ICH or LVO). All the non-enhanced head CT images and head CT angiographies studies received by CINA device are displayed in the worklist and those on which the algorithms have detected a suspected finding (ICH or LVO) are marked with an icon (i.e., passive notification). In addition, a compressed, small black and white image that is marked “not for diagnostic use” is displayed as a preview function. This compressed preview is meant for informational purposes only, does not contain any marking of the findings, and is not intended for primary diagnosis beyond notification. Presenting the radiologist with notification facilitates earlier triage by allowing one to prioritize images in the PACS. Thus, the suspect case receives attention earlier than would have been the case in the standard of care practice alone.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-B826CINA100 registered 21 Nov 2022 Active
  • FDA 510(k) K200855 decided 24 Jun 2020 Active
  • FDA GUDID UDI-DI B826CINA100 listed 14 Dec 2020 Listed

Timeline

3 dated events

  1. Cleared FDA 510(k) K200855
  2. Listed FDA GUDID B826CINA100
  3. Registered EUDAMED B-B826CINA100

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Generic name
Radiology DICOM image processing application software
Model / reference
++B826CINA10RR EUDAMED
1.0 GUDID
Primary DI / UDI-DI
B826CINA100
Basic UDI-DI
B-B826CINA100
510(k) Number
FDA product code
QAS
EMDN code
Z11039092 Various radiodiagnostic and interventional instruments - medical device software
GMDN term
Radiology DICOM image processing application software
Device class
Class I EUDAMED
Class II GUDID
Regulation number
892.2080
System or procedure pack
System which is a device in itself
EU registration type
Legacy device (under a directive)
EU market of registration
France
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
++B826CINA10RR
GUDID
1.0
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
FR-MF-000000324

Similar devices in this category

Other devices filed under VARIOUS RADIODIAGNOSTIC AND INTERVENTIONAL INSTRUMENTS - MEDICAL DEVICE SOFTWARE.

Other devices from Avicenna.ai

  • Cina-Vcf 1.0

    Class II
  • Cina-Aspects 1.5

    Class II
  • Cina Chest 1.0

    Class II
  • CINA-CSpine 1.0

    Class II

See all devices from Avicenna.ai →

Properties

  • Prescription use
  • Lot / batch number