Circuits
by Respironics Inc. 14 variants
Circuits (1074627) is a ventilator breathing circuit (FDA Class II; FDA product code CBK, Ventilator, Continuous, Facility Use) made by Respironics Inc., cleared under FDA 510(k) K093416 on 29 Jan 2010 and listed in FDA GUDID since 23 Oct 2015 (UDI-DI 00606959026070), active as of 23 Oct 2026. 5 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
2 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00606959026070 | Date23 Oct 2015 | StatusListed |
| United States | FDA 510(k)SESE | NumberK093416 | Date29 Jan 2010 | StatusActive |
Official records
- AccessGUDID record 00606959026070
- FDA 510(k) database K093416
From the FDA record
- Device description
- Disposable Adult Passive Circuit, No Water Trap
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K093416 decided 29 Jan 2010 Active
- FDA GUDID UDI-DI 00606959026070 listed 23 Oct 2015 Listed
Recalls
-
- Ongoing Z-0883-2023
The replacement silicone sound abatement foam installed into some Trilogy 100 and Trilogy 200 devices may separate from the plastic backing to which it is attached. If this were to happen, the foam could potentially block air inlet, which could result in a reduction in delivered therapy volume or pressure and could cause the device to alarm.
-
- Ongoing Z-1956-2021
The polyester-based polyurethane (PE-PUR) foam may degrade into particles which may enter the devices air pathway and be ingested or inhaled by the user, and the PE-PUR foam may off-gas certain chemicals.
-
- Terminated Z-1065-2016
Software Issue
-
- Terminated Z-1143-2014
Internal testing revealed a potentially defective component on the power management board that could affect the function of certain Trilogy Ventilators resulting in loss of therapy to patients.
-
- Terminated Z-2024-2012
The specified Trilogy units are being recalled because of the potential for a faulty component in the power supply.
Timeline
- Cleared FDA 510(k) K093416
- Recall initiated FDA recalls Z-2024-2012
- Recall initiated FDA recalls Z-1143-2014
- Listed FDA GUDID 00606959026070
- Recall initiated FDA recalls Z-1065-2016
- Recall initiated FDA recalls Z-1956-2021
- Recall initiated FDA recalls Z-0883-2023
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Generic name
- Ventilator breathing circuit, single-use
- Model / Ref / Catalog
- Disposable Adult Passive Circuit no H2O Trap, 1074627
- Primary DI / UDI-DI
- 00606959026070
- 510(k) Number
- FDA product code
- CBK
- GMDN term
- Ventilator breathing circuit, single-use
- Device class
- Class II
- Regulation number
- 868.5895
- GUDID distribution status
- In Commercial Distribution
Similar devices in this category
Other devices filed under Ventilator breathing circuit, single-use.
- Patient Circuit V64-0017 by FLIGHT MEDICAL INNOVATIONS LTD
- Neoforce NF-086U by FLEXICARE MEDICAL LIMITED
- F&P Evaqua 2 RT265 by FISHER & PAYKEL HEALTHCARE, INC.
- Adult Circ w/ Dual HTD/W & AutoFCh 038-31-748U by FLEXICARE MEDICAL LIMITED
- Patient Circuit V64-50130-90 by FLIGHT MEDICAL INNOVATIONS LTD
- VentStar Carina ExpV 200cm 5704962 by Drägerwerk AG & Co. KGaA
- Ventstar Oxylog 1000 180 2M86837 by Drägerwerk AG & Co. KGaA
- HAMILTON-BC8022 260161 by Hamilton Medical AG
- ValueTrac 313-9078 by Pulmodyne Inc.
- F&P Airvo 900PT561 by FISHER & PAYKEL HEALTHCARE, INC.