Clinical Neuro Systems Monitorr Icp Ventricular Ca
by Clinical Neuro Systems, LLC
510(k) K922941
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK922941 | Date26 Aug 1992 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- JXG
- Device Class
- Class II
- Regulation
- 21 CFR Part 882.5550
- Advisory Committee
- Neurology
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 19 Sep 2026
The Monitorr ICP Ventricular Catheter is a central nervous system shunt component designed to measure and monitor intracranial pressure (ICP). It is used to divert cerebrospinal fluid (CSF) from the brain’s ventricular system to an external drainage system or internal reservoir, thereby relieving elevated ICP or managing hydrocephalus.
This device is intended for single-use in clinical settings such as neurosurgical intensive care units or operating rooms. It is supplied sterile and must be handled under aseptic conditions. The catheter is classified as a Class II medical device under FDA regulation 882.5550, with an FDA 510(k) clearance (K922941) granted in 1992. Compatibility with MRI environments is not specified in the available data.
Other devices from Clinical Neuro Systems, LLC
Questions
AI-generated answers, 19 Sep 2026
What clinical settings is the Monitorr ICP Ventricular Catheter designed for use in?
The Monitorr ICP Ventricular Catheter is specifically intended for use in neurosurgical intensive care units (NICUs) and operating rooms. It is designed to measure intracranial pressure (ICP) and manage hydrocephalus by diverting cerebrospinal fluid (CSF) from the brain’s ventricular system to an external drainage system or internal reservoir.
Is the Monitorr ICP Ventricular Catheter meant for single-use or can it be reused?
The Monitorr ICP Ventricular Catheter is explicitly designed for single-use in clinical settings. It must be handled under aseptic conditions due to its sterile packaging, which aligns with its intended use in sterile environments like neurosurgical procedures.
What are the key features of the regulatory clearance for this device?
The Monitorr ICP Ventricular Catheter holds an FDA 510(k) clearance (K922941), granted in 1992 under the Traditional 510(k) review pathway. It is classified as a Class II medical device under FDA regulation 21 CFR 882.5550, with a substantially equivalent determination by the Neurology (NE) Advisory Committee. The product code assigned is JXG, reflecting its categorization as a shunt component for the central nervous system.
How should the Monitorr ICP Ventricular Catheter be stored before use?
The device is supplied sterile, so it must be stored in its original packaging to maintain sterility until use. Proper storage conditions—such as avoiding extreme temperatures or contamination—are critical, as the catheter is intended for immediate clinical use in sterile environments like operating rooms or NICUs.