Closed Suction System VR041110US
Ref VR041110ESModel 10FR,72H,Endotracheal,ES
Closed Suction System VR041110US is a heat/moisture exchanger (EU MDD Class IIa; FDA Class I; FDA product code BYD, Condenser, Heat And Moisture (Artificial Nose)) made by Vr Medical Technology, registered in EUDAMED on 5 Jun 2026 (Basic UDI-DI B-16959180704417) and listed in FDA GUDID since 6 May 2020 (UDI-DI 16959180704417), active as of 23 Oct 2026.
Active
Valid until
No date given
FDA recalls
Not checked
Documents
None linked in EUDAMED
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-16959180704417 16959180704417 | Date5 Jun 2026 | StatusActive |
| United States | GUDID listing GUDID | Number16959180704417 | Date6 May 2020 | StatusListed |
Official records
- EUDAMED public site B-16959180704417
- AccessGUDID record 16959180704417
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI B-16959180704417 registered 5 Jun 2026 Active
- FDA GUDID UDI-DI 16959180704417 listed 6 May 2020 Listed
Timeline
- Listed FDA GUDID 16959180704417
- Registered EUDAMED B-16959180704417
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Closed Suction System
- Generic name
- Heat/moisture exchanger, single-use
- Device name
- Disposable Closed Suction Catheter
- Model / reference
- 10FR EUDAMED72H EUDAMEDEndotracheal EUDAMEDES EUDAMEDVR041110ES EUDAMEDVR041110US GUDID
- Primary DI / UDI-DI
- 16959180704417
- Basic UDI-DI
- B-16959180704417
- FDA product code
- BYD
- EMDN code
- R050102 Closed-circuit respiratory suction and irrigation systems (non-endoscopic)
- GMDN term
- Heat/moisture exchanger, single-use
- Device class
- Class IIa EUDAMEDClass I GUDID
- Regulation number
- 868.5375
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Spain
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 10FR,72H,Endotracheal,ES VR041110ES | VR041110US |
| Device class | Class IIa | Class I |
| Supplied sterile | Yes | No |
Registry differences
EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:
- Supplied sterile UDI-DI 16959180704417: EUDAMED states Yes, FDA GUDID states No.
Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class I in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.
Similar devices in this category