# Cls L2.0

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/cls-l2-0-701049252>
- Manufacturer: [Maquet Cardiopulmonary GmbH](https://devicerts.com/manufacturers/maquet-cardiopulmonary-gmbh) (Germany)
- Name in the registry: CLS L2.0
- Device class: Class IIb (EU MDD); Class II (US FDA)
- FDA product code: DTQ
- EMDN: Z12050280 EXTRA-CORPOREAL CIRCULATION INSTRUMENTS - HARDWARE ACCESSORIES
- GMDN: Cardiopulmonary bypass system air bubble/fluid level detector (35440)

## Registrations and authorizations

- **EUDAMED** · CE/MDD · European Union · Basic UDI-DI B-04037691682907 · UDI-DI 04037691682907 · registered 2026-04-10 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 04037691682907 · listed 2018-10-26 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K102726 · decision 2011-04-04 · decision SESE · status: Active · from GUDID

## Recalls

- Z-1823-2025 · Class II · ongoing · initiated 2025-04-30: HKH 8820 Wall Holder does not comply with standard DIN EN 1789:20 and has the potential to detach.
- Z-1662-2023 · Class II · ongoing · initiated 2023-05-18 · matched through shared submission K102726, may concern other models: Product packaging may exhibit small pinholes which may not be visible to the unaided eye, compromising the sterile barrier of the packaging. Exposure to non-sterile device may result in inflammation, infection, sepsis, and ischemia.
- Z-1643-2023 · Class II · ongoing · initiated 2023-05-18: 1. An accessory may be improperly placed during packaging, causing creases and damage to the accessory's sterile pouch. 2. Product packaging may exhibit holes, cracks, dents, and crushed areas. Both issues may compromise the sterile barrier of the packaging, and exposure to non-sterile product may result in inflammation, infection, sepsis, and ischemia.
- Z-0986-2019 · Class I · terminated · initiated 2019-02-08: Upon servicing the gearwheel in the Emergency Drive the gearwheel may have been re-assembled incorrectly, leading to the inadequate operation of the Emergency Drive.
- Z-1642-2018 · Class II · terminated · initiated 2018-04-04 · matched through shared submission K102726, may concern other models: There is a possibility for the clamps of the gas bottle holder to crack or break when exposed to strong vibrations.
- Z-1372-2016 · Class II · terminated · initiated 2016-02-23: Maquet Cardiopulmonary (MCP) is conducting a voluntary recall based on the potential risk of exposure to endotoxin for various products.
- Z-1690-2015 · Class II · terminated · initiated 2015-03-05: A potential issue was detected that could result in blood leakage from the gas outlet port in all lots of Quadrox-iD Adult Diffusion Membrane Oxygenator with Bioline and Softline Coatings, Custom Tubing Packs and Diffusion Membrane HLS Set Advanced and HIT Set Advanced Models.
- Z-0211-2015 · Class II · terminated · initiated 2014-10-17: Cardiohelp- i System may have a software issue that can potentially result in an erroneous display of a "Battery Needs Service" message after startup of the units when using either AC or DC power
- Z-0082-2014 · Class II · terminated · initiated 2013-09-12: It has come to the attention of MAQUET that in certain rare instances, the CARDIOHELP-i device may display an error message with audible alarm, indicating "battery defective." The alarm will occur-upon start up or when the main power supply is unplugged from the main power source. The human machine interface touch screen of the CARDIOHELP-i device may gradually become black due to the human machine interface (HMI) back light shutting down.
- Z-1149-2013 · Class II · terminated · initiated 2013-03-07: It has come to the attention of MAQUET that there have been episodes of brief unexpected shutdown, followed by an automatic device restart of the human machine interface (touch screen) of the CARDIOHELP device. The human machine interface (HMI) is the central display of the CARDIOHELP device, where measured values, settings and alarms are displayed and adjusted/confirmed, with the exception of bl

## Identity

- Trade name: CLS L2.0 [EUDAMED]; CARDIOHELP System [FDA GUDID (AccessGUDID)]
- Generic name: Cardiopulmonary bypass system air bubble/fluid level detector [FDA GUDID (AccessGUDID)]
- Model / Ref / Catalog: 701049252 [EUDAMED]; CLS L2.0 [FDA GUDID (AccessGUDID)]; 70104.9252 [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 04037691682907 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: B-04037691682907 [EUDAMED]
- 510(k) Number: K102726 [FDA GUDID (AccessGUDID)]
- FDA product code: DTQ [FDA GUDID (AccessGUDID)]
- EMDN code: Z12050280 [EUDAMED]
- GMDN term: Cardiopulmonary bypass system air bubble/fluid level detector (35440) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class IIb [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 870.4220 [FDA GUDID (AccessGUDID)]
- EU registration type: Legacy device (under a directive) [EUDAMED]
- EU market of registration: Germany [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Serial number: Yes [FDA GUDID (AccessGUDID)]
- Manufacturing date: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Lot / batch number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Cls L2.0, Maquet Cardiopulmonary GmbH. deviCERTS medical device catalogue. https://devicerts.com/devices/cls-l2-0-701049252 (data as of 2026-11-18).
- Data sources: [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-18
- JSON: <https://devicerts.com/devices/cls-l2-0-701049252.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.