Skip to content

Clx Acetabular Cup (Wagner) for Cementless Fixat.

by Protek, Inc.

510(k) K870924

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK870924 Date14 Sep 1987ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
KWA
Device Class
Class III
Regulation
21 CFR Part 888.3330
Advisory Committee
Orthopedic
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The CLX Acetabular Cup (Wagner) is a semi-constrained, metal uncemented acetabular component designed for hip arthroplasty. It is intended to provide a stable fixation interface within the pelvis without the use of bone cement, facilitating long-term integration with the host bone.

This device is supplied as a reusable orthopedic implant, intended for use in surgical settings by trained professionals. It is classified under FDA regulation 888.3330 and received a 510(k) clearance (K870924) in 1987, with multiple associated registration numbers. The Wagner design is intended for cementless fixation, ensuring compatibility with standard orthopedic surgical procedures.

Other devices from Protek, Inc.

See all devices from Protek, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What type of hip implant is the CLX Acetabular Cup (Wagner) designed for, and how does it differ from cemented alternatives?

    The CLX Acetabular Cup (Wagner) is a semi-constrained, metal uncemented acetabular component specifically designed for cementless hip arthroplasty. Unlike cemented alternatives, it is engineered to integrate directly with the host bone over time, eliminating the need for bone cement while providing a stable fixation interface in the pelvis. This design is intended to facilitate long-term bone integration, reducing the risk of loosening associated with cemented implants.

  • Is the CLX Acetabular Cup reusable or single-use, and how should it be handled in the operating room?

    The CLX Acetabular Cup is reusable, meaning it is intended for multiple surgical uses under strict sterilization protocols. As a reusable orthopedic implant, it must be properly cleaned, inspected, and sterilized between cases to maintain safety and performance. This aligns with standard practices for high-value surgical implants in orthopedic procedures.

  • What regulatory pathway was followed for FDA clearance of this device, and when was it originally approved?

    The CLX Acetabular Cup received FDA 510(k) clearance (K870924) under the Traditional 510(k) pathway in 1987, with a decision date of September 14, 1987. It was classified as Substantially Equivalent (SESE) to a predicate device and falls under FDA regulation 888.3330, which governs acetabular components for hip replacements. The device is categorized under the Orthopedic (OR) Advisory Committee and is listed as a Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component).

  • Are there multiple sizes or models available for the CLX Acetabular Cup, and how does this affect surgical planning?

    While the provided data does not specify exact sizes or models, the CLX Acetabular Cup is part of a registered product family with multiple FEI (Facility Establishment Identifier) and registration numbers, indicating variability in inventory or inventory tracking. Clinicians should confirm available sizes with the manufacturer or distributor during surgical planning to ensure compatibility with the patient’s anatomy and the intended procedure. This variability is typical for reusable orthopedic implants to accommodate different patient anatomies.