Skip to content

ComASP Cefiderocol 0.008-128

by Liofilchem S.r.l.

510(k) K230479

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 6 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK230479 Date18 May 2023ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 6 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
JWY
Device Class
Class II
Regulation
21 CFR Part 866.1640
Advisory Committee
Microbiology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The ComASP Cefiderocol 0.008–128 is a Manual Antimicrobial Susceptibility Test System designed for in vitro antimicrobial susceptibility testing (AST). It quantifies the minimum inhibitory concentration (MIC) of cefiderocol against Gram-negative non-fastidious organisms, including Enterobacterales, Pseudomonas aeruginosa, Acinetobacter spp., and Stenotrophomonas maltophilia. The system employs a broth microdilution method with dried antibiotic dilutions ranging from 0.008 to 128 µg/mL to assess bacterial susceptibility.

This single-use, non-sterile test panel is supplied as a 2-test panel for qualitative determination of cefiderocol efficacy. It is intended for use in microbiology laboratories and adheres to regulatory standards under FDA 510(k) clearance (K230479). Storage and handling follow standard in vitro diagnostic procedures, with no MRI compatibility requirements. The product is classified under device class II and regulated under 21 CFR 866.1640 for antimicrobial susceptibility testing systems.

Other devices from Liofilchem S.r.l.

See all devices from Liofilchem S.r.l. →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the ComASP Cefiderocol 0.008–128 used for?

    This system performs in vitro antimicrobial susceptibility testing (AST) to determine the minimum inhibitory concentration (MIC) of cefiderocol against Gram-negative non-fastidious organisms. These include *Enterobacterales*, *Pseudomonas aeruginosa*, *Acinetobacter* spp., and *Stenotrophomonas maltophilia*. The results help guide treatment decisions by quantifying bacterial susceptibility to cefiderocol using a broth microdilution method with dried antibiotic dilutions ranging from 0.008 to 128 µg/mL.

  • How is the ComASP Cefiderocol 0.008–128 supplied and what is its sterility status?

    The system is supplied as a single-use, non-sterile 2-test panel. Each panel contains dried antibiotic dilutions for qualitative determination of cefiderocol efficacy. Since it is non-sterile, it must be handled in accordance with standard microbiology laboratory practices to prevent contamination during testing.

  • Can this test system be reused, and what storage requirements apply?

    The ComASP Cefiderocol 0.008–128 is designed for single-use only. Storage should follow standard in vitro diagnostic procedures, though specific conditions (e.g., temperature, humidity) are not detailed in the data. Laboratories should refer to manufacturer guidelines for optimal storage to maintain test integrity.

  • What regulatory pathway does this device follow?

    The ComASP Cefiderocol 0.008–128 is cleared under the FDA’s 510(k) pathway (K230479) as substantially equivalent to a predicate device. It is classified under device class II and regulated under 21 CFR 866.1640 for antimicrobial susceptibility testing systems. The decision was reviewed by the Microbiology Advisory Committee.

  • Does this system require special handling or compatibility considerations?

    The system does not have MRI compatibility requirements. It is intended for use in microbiology laboratories and adheres to standard AST procedures. Handling should avoid contamination, as it is non-sterile, and follow manufacturer instructions for accurate results.