comknife® JPD-BL-B-117
by Beijing Bohai Kangyuan Medical Devices Co., Ltd.
Ref BL-B-117Model JPD
comknife JPD-BL-B-117 is a scalpel (EU MDD Class IIa; FDA Class I; FDA product code GDZ, Handle, Scalpel) made by Beijing Bohai Kangyuan Medical Devices Co., Ltd., registered in EUDAMED on 19 May 2026 (Basic UDI-DI B-06971503609998) and listed in FDA GUDID since 26 Aug 2025 (UDI-DI 06971503609998), active as of 22 Oct 2026.
Active
Valid until
No date given
FDA recalls
Not checked
Documents
None linked in EUDAMED
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-06971503609998 06971503609998 | Date19 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number06971503609998 | Date26 Aug 2025 | StatusListed |
Official records
- EUDAMED public site B-06971503609998
- AccessGUDID record 06971503609998
From the FDA record
- Device description
- Are intended for delicate dissection and stripping of blood vessels and soft tissues in surgery or microsurgery
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as containing natural rubber latex
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI B-06971503609998 registered 19 May 2026 Active
- FDA GUDID UDI-DI 06971503609998 listed 26 Aug 2025 Listed
Timeline
- Listed FDA GUDID 06971503609998
- Registered EUDAMED B-06971503609998
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- comknife®
- Generic name
- Scalpel, single-use
- Device name
- Disposable Microsurgical Scalpels
- Model / reference
- JPD EUDAMEDBL-B-117 EUDAMEDJPD-BL-B-117 GUDID
- Primary DI / UDI-DI
- 06971503609998
- Basic UDI-DI
- B-06971503609998
- FDA product code
- GDZ
- EMDN code
- V010102 Scalpels without safety systems, single-use
- GMDN term
- Scalpel, single-use
- Device class
- Class IIa EUDAMEDClass I GUDID
- Regulation number
- 878.4800
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | JPD BL-B-117 | JPD-BL-B-117 |
| Device class | Class IIa | Class I |
| Contains latex | No | Yes |
Registry differences
EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:
- Contains latex UDI-DI 06971503609998: EUDAMED states No, FDA GUDID states Yes.
Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class I in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.
Similar devices in this category
Other devices filed under SCALPELS WITHOUT SAFETY SYSTEMS, SINGLE-USE.
- KIATO 11P 14831 by ADITYA DISPOMED PRODUCTS PRIVATE LIMITED
- KIATO 12 14812 by ADITYA DISPOMED PRODUCTS PRIVATE LIMITED
- Disposable Microsurgical Scalpels MC-L-249 by Beijing Bohaikangyuan Medical Devices Co., Ltd.
- Disposable Microsurgical Scalpels QG-L-278 by Beijing Bohaikangyuan Medical Devices Co., Ltd.
- EXEL SCALPELS, S-S, SIZE:11 29552 by Exelint International, Co.
- EXEL SCALPELS, S-S, SIZE:22 29559 by Exelint International, Co.
Other devices from Beijing Bohai Kangyuan Medical Devices Co., Ltd.
See all devices from Beijing Bohai Kangyuan Medical Devices Co., Ltd. →