# Component Neuromonitoring System

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/component-neuromonitoring-system-oma>
- Manufacturer: [Moberg Research, Inc.](https://devicerts.com/manufacturers/moberg-research-inc) (United States)
- Name in the registry: COMPONENT NEUROMONITORING SYSTEM
- Device class: Class II (US FDA)
- FDA product code: OMA

## Overview

*AI-generated summary, 2026-10-01. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The Component Neuromonitoring System is an Amplitude-Integrated Electroencephalograph (aEEG), a Class II medical device designed for continuous monitoring of brain function. It provides real-time assessment of neurological activity, particularly in critical care settings, by integrating and analyzing EEG signals to detect and evaluate brain injury, seizures, or other neurological conditions. This device supports multimodal neuromonitoring by synchronizing data from multiple sources, enabling comprehensive patient assessment.

This system is intended for use in clinical environments where neurological monitoring is required, such as intensive care units (ICUs) or neurocritical care settings. It is supplied as a reusable device, adhering to regulatory standards including FDA 510(k) clearance under the Neurology advisory committee. The system operates in non-MRI environments and is not classified as sterile or single-use. Storage and handling follow standard medical device protocols, with compliance ensured through the assigned OpenFDA registration numbers and product code OMA.

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K080217 · decision 2008-11-05 · decision SESE · status: Active

## Recalls

- Z-1338-2023 · Class II · ongoing · initiated 2023-02-20: Battery leakage can cause corrosion to the metal enclosure near the electrical interface. Prolonged contact to corrosive materials could cause injury to skin. DOC

## Identifiers

- 510(k) Number: K080217 [FDA 510(k)]
- FDA product code: OMA [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 882.1400 [FDA 510(k)]
- Advisory committee: Neurology [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: Component Neuromonitoring System, Moberg Research, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/component-neuromonitoring-system-oma (data as of 2026-11-25).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-05
- Statuses computed as of: 2026-11-25
- JSON: <https://devicerts.com/devices/component-neuromonitoring-system-oma.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/component-neuromonitoring-system-oma
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.