Comprehensive® Instrumentation 405970
Listed
Valid until
Not applicable
FDA recalls
None ongoingDocuments
None
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00887868504907 | Date8 May 2022 | StatusListed |
Recalls
-
- Terminated Z-1131-2021
Zimmer Biomet is conducting a lot specific medical device recall for the Comprehensive Reverse Shoulder Central Screw, 25 MM Length. It has been determined through a complaint investigation that a 40 MM length central screw was packaged and labeled as a 25 MM length central screw.
-
- Terminated Z-0619-2021
Specific lots of multiple sterile medical devices may have a breach in the sterile seal. A breach in the packaging seal could lead to loss of sterility of the device.
-
- Terminated Z-0093-2021
Product potentially being packaged without a taper adapter or baseplate. The package should contain one (1) baseplate and one (1) taper adapter, product may be packaged with two (2) baseplates and no (0) adapters or with no (0) baseplates and two (2) adapters
-
- Terminated Z-2144-2020
Potential presence of elevated endotoxin levels that exceed the specification limit
-
- Terminated Z-1750-2020
There were unknown bioburden levels prior to sterilization, which may affect sterility of the product.
-
- Terminated Z-1859-2017
Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components.
-
- Terminated Z-1103-2017
Higher than anticipated rate of fracturing due to design. Risk of revision surgery due to fracturing.
-
- Terminated Z-1548-2013
Biomet has initiated this action following an investigation which identified that the slot on the resection guide is offset in the wrong direction. When the slot on the resection guide is offset in the wrong direction, the Steinman pin that is intended to hold the guide into place may not come into contact with the bone.
-
- Terminated Z-2548-2011
- Terminated Z-2547-2011
- Terminated Z-2550-2011
- Terminated Z-2546-2011
- Terminated Z-2542-2011
- Terminated Z-2545-2011
- Terminated Z-2541-2011
- Terminated Z-2549-2011
- Terminated Z-2544-2011
- Terminated Z-2543-2011
The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled.
-
- Terminated Z-0712-2011
- Terminated Z-0713-2011
The firm received complaints regarding fracturing of the device.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — GUDID listing Listed
Specification
- Trade Name
- Comprehensive® Instrumentation
- Generic Name
- Humeral head prosthesis trial, reusable
- Model / Ref / Catalog
- 405970
- Primary DI / UDI-DI
- 00887868504907
- FDA Product Code
- KWS, PAO, PHX, HWT
- GMDN Term
- Humeral head prosthesis trial, reusable
- Device Class
- Class II
- Regulation Number
- 888.3660, 888.4800
- GUDID distribution status
- In Commercial Distribution
- Sterilization Method
- Moist Heat or Steam Sterilization
Other devices from Biomet Orthopedics, Inc.
Properties
Other properties (12)
- Sterile: No
- Single Use: No
- Implantable: No
- Contains Latex: No
- Over-the-Counter: No
- Convenience Kit: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Serial Number: No
- Expiration Date: No
- Manufacturing Date: No