Comprehensive® Reverse Shoulder 110010424
Ref 110010424
Comprehensive Reverse Shoulder 110010424 is a surgical screwdriver (EU MDR Class I; FDA Class II) made by Biomet Orthopedics, Inc., registered in EUDAMED on 1 Nov 2026 (Basic UDI-DI 889024-ZB001491-G5), cleared under FDA 510(k) K080642 on 9 Jul 2008 and listed in FDA GUDID since 23 Mar 2021 (UDI-DI 00887868465772), active as of 7 Nov 2026. 15 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number889024-ZB001491-G5 00887868465772 | Date1 Nov 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00887868465772 | Date23 Mar 2021 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK080642 | Date9 Jul 2008 | StatusActive |
Official records
- EUDAMED public site 889024-ZB001491-G5
- AccessGUDID record 00887868465772
- FDA 510(k) database K080642
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI 889024-ZB001491-G5 registered 1 Nov 2026 Active
- FDA 510(k) K080642 decided 9 Jul 2008 Active
- FDA GUDID UDI-DI 00887868465772 listed 23 Mar 2021 Listed
Recalls
-
- Terminated Z-2144-2020
Potential presence of elevated endotoxin levels that exceed the specification limit
-
- Terminated Z-1750-2020
There were unknown bioburden levels prior to sterilization, which may affect sterility of the product.
-
- Terminated Z-1859-2017
Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components.
-
- Terminated Z-1103-2017
Higher than anticipated rate of fracturing due to design. Risk of revision surgery due to fracturing.
-
- Terminated Z-1548-2013
Biomet has initiated this action following an investigation which identified that the slot on the resection guide is offset in the wrong direction. When the slot on the resection guide is offset in the wrong direction, the Steinman pin that is intended to hold the guide into place may not come into contact with the bone.
-
- Terminated Z-2541-2011
- Terminated Z-2542-2011
- Terminated Z-2543-2011
- Terminated Z-2544-2011
- Terminated Z-2545-2011
- Terminated Z-2546-2011
- Terminated Z-2547-2011
- Terminated Z-2548-2011
- Terminated Z-2549-2011
- Terminated Z-2550-2011
The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled.
-
- Terminated Z-0712-2011
- Terminated Z-0713-2011
The firm received complaints regarding fracturing of the device.
Timeline
- Recall initiated FDA recalls Z-2548-2011
- Recall initiated FDA recalls Z-2549-2011
- Recall initiated FDA recalls Z-2550-2011
- Recall initiated FDA recalls Z-1548-2013
- Recall initiated FDA recalls Z-1103-2017
- Recall initiated FDA recalls Z-1859-2017
- Recall initiated FDA recalls Z-1750-2020
- Recall initiated FDA recalls Z-2144-2020
- Listed FDA GUDID 00887868465772
- Registered EUDAMED 889024-ZB001491-G5
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Comprehensive® Reverse Shoulder
- Generic name
- Surgical screwdriver, reusable
- Device name
- Comp 3_5mm Hex Driver
- Model / Ref / Catalog
- 110010424
- Primary DI / UDI-DI
- 00887868465772
- Basic UDI-DI
- 889024-ZB001491-G5
- Direct marketing DI
- 00887868465772
- 510(k) Number
- FDA product code
- KWS, PAO
- EMDN code
- L091199 Orthopaedic prosthetics instruments, reusable - other
- GMDN term
- Surgical screwdriver, reusable
- Device class
- Class I EUDAMEDClass II GUDID
- Regulation number
- 888.3660
- EU registration type
- Standard device
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class I | Class II |
Similar devices in this category
Other devices filed under ORTHOPAEDIC PROSTHETICS INSTRUMENTS, REUSABLE - OTHER.
- SIGMA 96-1779 by DePuy Ireland UC
- USTAR II Knee System 2815-2251 by UNITED ORTHOPEDIC CORP.
- 164505-01 by MAKO Surgical Corp.
- Continuum® Trilogy® Allofit® 00-8734-021-32 by Zimmer, Inc.
- Trabecular Metal® 00-7865-035-22 by Zimmer, Inc.
- PHYSICA ZUK Instrument Set - Slap Hammer 9061.10.025 by LIMACORPORATE S.p.A.
- HIP Instruments 01.36.10.0162 by Medacta International SA
- ORTHOPEDIC MANUAL SURGICAL INSTRUMENT 906-0007 by FX SOLUTIONS
- ORTHOPEDIC MANUAL SURGICAL INSTRUMENT 951-0078 by FX SOLUTIONS
- ACS® 42130326 by implantcast GmbH