Skip to content

Comprehensive® Reverse Shoulder 110010424

by Biomet Orthopedics, Inc.

Ref 110010424

Comprehensive Reverse Shoulder 110010424 is a surgical screwdriver (EU MDR Class I; FDA Class II) made by Biomet Orthopedics, Inc., registered in EUDAMED on 1 Nov 2026 (Basic UDI-DI 889024-ZB001491-G5), cleared under FDA 510(k) K080642 on 9 Jul 2008 and listed in FDA GUDID since 23 Mar 2021 (UDI-DI 00887868465772), active as of 7 Nov 2026. 15 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

17 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K080642

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number889024-ZB001491-G5 Basic UDI-DI 00887868465772UDI-DIDate1 Nov 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00887868465772 UDI-DI Date23 Mar 2021ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK080642 Date9 Jul 2008DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 889024-ZB001491-G5 registered 1 Nov 2026 Active
  • FDA 510(k) K080642 decided 9 Jul 2008 Active
  • FDA GUDID UDI-DI 00887868465772 listed 23 Mar 2021 Listed

Recalls

17 recalls · FDA

    • Terminated Z-2144-2020 FDA Class II initiated 17 Apr 2020 on shared 510(k) K080642

    Potential presence of elevated endotoxin levels that exceed the specification limit

    • Terminated Z-1750-2020 FDA Class II initiated 13 Mar 2020 on shared 510(k) K080642

    There were unknown bioburden levels prior to sterilization, which may affect sterility of the product.

    • Terminated Z-1859-2017 FDA Class II initiated 17 Feb 2017

    Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components.

    • Terminated Z-1103-2017 FDA Class I initiated 20 Dec 2016

    Higher than anticipated rate of fracturing due to design. Risk of revision surgery due to fracturing.

    • Terminated Z-1548-2013 FDA Class II initiated 15 May 2013

    Biomet has initiated this action following an investigation which identified that the slot on the resection guide is offset in the wrong direction. When the slot on the resection guide is offset in the wrong direction, the Steinman pin that is intended to hold the guide into place may not come into contact with the bone.

  • 10 recalls, same reason

    • Terminated Z-2541-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2542-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2543-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2544-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2545-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2546-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2547-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2548-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2549-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2550-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011

    The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled.

  • 2 recalls, same reason

    • Terminated Z-0712-2011 FDA Unclassified (pre-2012) initiated 13 Sep 2010
    • Terminated Z-0713-2011 FDA Unclassified (pre-2012) initiated 13 Sep 2010

    The firm received complaints regarding fracturing of the device.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

20 dated events

  1. Recall initiated FDA recalls Z-2548-2011
  2. Recall initiated FDA recalls Z-2549-2011
  3. Recall initiated FDA recalls Z-2550-2011
  4. Recall initiated FDA recalls Z-1548-2013
  5. Recall initiated FDA recalls Z-1103-2017
  6. Recall initiated FDA recalls Z-1859-2017
  7. Recall initiated FDA recalls Z-1750-2020
  8. Recall initiated FDA recalls Z-2144-2020
  9. Listed FDA GUDID 00887868465772
  10. Registered EUDAMED 889024-ZB001491-G5

10 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Comprehensive® Reverse Shoulder
Generic name
Surgical screwdriver, reusable
Device name
Comp 3_5mm Hex Driver
Model / Ref / Catalog
110010424
Primary DI / UDI-DI
00887868465772
Basic UDI-DI
889024-ZB001491-G5
Direct marketing DI
00887868465772
510(k) Number
FDA product code
KWS, PAO
EMDN code
L091199 Orthopaedic prosthetics instruments, reusable - other
GMDN term
Surgical screwdriver, reusable
Device class
Class I EUDAMED
Class II GUDID
Regulation number
888.3660
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under ORTHOPAEDIC PROSTHETICS INSTRUMENTS, REUSABLE - OTHER.

Other devices from Biomet Orthopedics, Inc.

See all devices from Biomet Orthopedics, Inc. →

Properties

  • Sterilise before use
  • Reusable
  • Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction)
  • Prescription use
  • Lot / batch number
Other properties (20, all answered No)