Skip to content

Comprehensive® Reverse Shoulder 406202

by Biomet Orthopedics, Inc.

Ref 406202

Comprehensive® Reverse Shoulder 406202 is a device classified as Class I in the EU and Class II in the US made by Biomet Orthopedics, Inc., registered in EUDAMED on 30 Oct 2026 (Basic UDI-DI 889024-ZB002636-GF), cleared under FDA 510(k) K193373 on 15 Apr 2020 (1 earlier submission) and listed in FDA GUDID since 23 Apr 2022 (UDI-DI 00887868519291), active as of 7 Nov 2026. 19 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

19 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number889024-ZB002636-GF Basic UDI-DI 00887868519291UDI-DIDate30 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00887868519291 UDI-DI Date23 Apr 2022ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK193373 Date15 Apr 2020DecidedStatusActive

Official records

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 889024-ZB002636-GF registered 30 Oct 2026 Active
  • FDA 510(k) K193373 decided 15 Apr 2020 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00887868519291 listed 23 Apr 2022 Listed

Recalls

19 recalls · FDA

    • Terminated Z-0619-2021 FDA Class II initiated 25 Nov 2020

    Specific lots of multiple sterile medical devices may have a breach in the sterile seal. A breach in the packaging seal could lead to loss of sterility of the device.

    • Terminated Z-0093-2021 FDA Class II initiated 2 Sep 2020

    Product potentially being packaged without a taper adapter or baseplate. The package should contain one (1) baseplate and one (1) taper adapter, product may be packaged with two (2) baseplates and no (0) adapters or with no (0) baseplates and two (2) adapters

    • Terminated Z-2144-2020 FDA Class II initiated 17 Apr 2020

    Potential presence of elevated endotoxin levels that exceed the specification limit

    • Terminated Z-1750-2020 FDA Class II initiated 13 Mar 2020

    There were unknown bioburden levels prior to sterilization, which may affect sterility of the product.

    • Terminated Z-1859-2017 FDA Class II initiated 17 Feb 2017

    Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components.

    • Terminated Z-1103-2017 FDA Class I initiated 20 Dec 2016

    Higher than anticipated rate of fracturing due to design. Risk of revision surgery due to fracturing.

    • Terminated Z-1548-2013 FDA Class II initiated 15 May 2013

    Biomet has initiated this action following an investigation which identified that the slot on the resection guide is offset in the wrong direction. When the slot on the resection guide is offset in the wrong direction, the Steinman pin that is intended to hold the guide into place may not come into contact with the bone.

  • 10 recalls, same reason

    • Terminated Z-2549-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2548-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2547-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2550-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2546-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2542-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2545-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2541-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2544-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2543-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011

    The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled.

  • 2 recalls, same reason

    • Terminated Z-0712-2011 FDA Unclassified (pre-2012) initiated 13 Sep 2010
    • Terminated Z-0713-2011 FDA Unclassified (pre-2012) initiated 13 Sep 2010

    The firm received complaints regarding fracturing of the device.

Timeline

23 dated events

  1. Recall initiated FDA recalls Z-1548-2013
  2. Recall initiated FDA recalls Z-1103-2017
  3. Recall initiated FDA recalls Z-1859-2017
  4. Recall initiated FDA recalls Z-1750-2020
  5. Cleared FDA 510(k) K193373
  6. Recall initiated FDA recalls Z-2144-2020
  7. Recall initiated FDA recalls Z-0093-2021
  8. Recall initiated FDA recalls Z-0619-2021
  9. Listed FDA GUDID 00887868519291
  10. Registered EUDAMED 889024-ZB002636-GF

13 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Comprehensive® Reverse Shoulder
Generic name
Shoulder glenoid fossa prosthesis, prefabricated
Device name
Comp Rvs Baseplate Sizers
Model / Ref / Catalog
406202
Primary DI / UDI-DI
00887868519291
Basic UDI-DI
889024-ZB002636-GF
Direct marketing DI
00887868519291
510(k) Number
FDA product code
PHX, KWS, PAO
EMDN code
L091104 Orthopaedic prostheses positioners, reusable
GMDN term
Shoulder glenoid fossa prosthesis, prefabricated
Device class
Class I EUDAMED
Class II GUDID
Regulation number
888.3660
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class II
ImplantableEUDAMED
No
GUDID
Yes

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under ORTHOPAEDIC PROSTHESES POSITIONERS, REUSABLE.

Other devices from Biomet Orthopedics, Inc.

See all devices from Biomet Orthopedics, Inc. →

Properties

  • Sterilise before use
  • Implantable NoEUDAMEDYesGUDID
  • Reusable
  • Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction)
  • Prescription use
  • Lot / batch number
Other properties (19, all answered No)