Comprehensive® Reverse Shoulder Instrument 405909
Ref 405909
Comprehensive Reverse Shoulder Instrument 405909 is an orthopaedic implant-instrument extension adaptor (EU MDR Class I; FDA Class II) made by Biomet Orthopedics, Inc., registered in EUDAMED on 31 Oct 2026 (Basic UDI-DI 889024-ZB002651-GA), cleared under FDA 510(k) K193373 on 15 Apr 2020 (1 earlier submission) and listed in FDA GUDID since 23 Apr 2022 (UDI-DI 00887868504808), active as of 7 Nov 2026. 5 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number889024-ZB002651-GA 00887868504808 | Date31 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00887868504808 | Date23 Apr 2022 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK193373 | Date15 Apr 2020 | StatusActive |
Official records
- EUDAMED public site 889024-ZB002651-GA
- AccessGUDID record 00887868504808
- FDA 510(k) database K193373
- FDA 510(k) database K120121
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI 889024-ZB002651-GA registered 31 Oct 2026 Active
- FDA 510(k) K193373 decided 15 Apr 2020 Active
- FDA GUDID UDI-DI 00887868504808 listed 23 Apr 2022 Listed
Recalls
-
- Terminated Z-0619-2021
Specific lots of multiple sterile medical devices may have a breach in the sterile seal. A breach in the packaging seal could lead to loss of sterility of the device.
-
- Terminated Z-0093-2021
Product potentially being packaged without a taper adapter or baseplate. The package should contain one (1) baseplate and one (1) taper adapter, product may be packaged with two (2) baseplates and no (0) adapters or with no (0) baseplates and two (2) adapters
-
- Terminated Z-1615-2020
Package is intended to contain one (1) baseplate and one (1) taper adapter; however, devices may be packaged with two (2) baseplates and no (0) adapters.
-
- Terminated Z-0972-2019
The product was potentially being packaged without a taper adapter.
-
- Terminated Z-1208-2015
The taper adaptor is missing from the packaging, which may result in a delay in surgery greater than 30 minutes.
Timeline
- Cleared FDA 510(k) K120121
- Recall initiated FDA recalls Z-1208-2015
- Recall initiated FDA recalls Z-0972-2019
- Recall initiated FDA recalls Z-1615-2020
- Cleared FDA 510(k) K193373
- Recall initiated FDA recalls Z-0093-2021
- Recall initiated FDA recalls Z-0619-2021
- Listed FDA GUDID 00887868504808
- Registered EUDAMED 889024-ZB002651-GA
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Comprehensive® Reverse Shoulder Instrument
- Generic name
- Orthopaedic implant-instrument extension adaptor, reusable
- Device name
- Comp Calcar Planer Shaft 25mm
- Model / Ref / Catalog
- 405909
- Primary DI / UDI-DI
- 00887868504808
- Basic UDI-DI
- 889024-ZB002651-GA
- Direct marketing DI
- 00887868504808
- FDA product code
- KWS, PHX
- EMDN code
- L091199 Orthopaedic prosthetics instruments, reusable - other
- GMDN term
- Orthopaedic implant-instrument extension adaptor, reusable
- Device class
- Class I EUDAMEDClass II GUDID
- Regulation number
- 888.3660
- EU registration type
- Standard device
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class I | Class II |
Similar devices in this category
Other devices filed under ORTHOPAEDIC PROSTHETICS INSTRUMENTS, REUSABLE - OTHER.
- Synergy Disc Tamps 1077-5280 by Synergy Spine Solutions Inc.
- Trabecular Metal® 00-4501-025-00 by Zimmer, Inc.
- Continuum® Trilogy® 00-8831-020-40 by Zimmer, Inc.
- QUANTUM M05 00791 by In2Bones, USA
- PHYSICA system 9095.11.12A by Limacorporate
- DCI™ CBT10001 by Paradigm Spine GmbH
- U2™ Hip 1201-2028-RB by UNITED ORTHOPEDIC CORP.
- Hip Instruments 01.10.10.045 by Medacta International SA
- Surgical Manual Instrument 01.20.10.011 by Medacta International SA
- CHESAPEAKE® Stabilization System 3608-90007 by VB Spine LLC