Skip to content

Comprehensive® Shoulder Instruments 41-406804

by Biomet Orthopedics, Inc.

Ref 41-406804

Comprehensive® Shoulder Instruments 41-406804 is a device classified as Class I in the EU and Class II in the US made by Biomet Orthopedics, Inc., registered in EUDAMED on 30 Oct 2026 (Basic UDI-DI 889024-ZB001980-GY), cleared under FDA 510(k) K193038 on 28 Oct 2020 (1 earlier submission) and listed in FDA GUDID since 2 Apr 2022 (UDI-DI 00887868506499), active as of 7 Nov 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number889024-ZB001980-GY Basic UDI-DI 00887868506499UDI-DIDate30 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00887868506499 UDI-DI Date2 Apr 2022ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK193038 Date28 Oct 2020DecidedStatusActive

Official records

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 889024-ZB001980-GY registered 30 Oct 2026 Active
  • FDA 510(k) K193038 decided 28 Oct 2020 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00887868506499 listed 2 Apr 2022 Listed

Recalls

1 recall · 1 ongoing · FDA

    • Ongoing Z-1403-2025 FDA Class II initiated 3 Mar 2025

    Five complaints received where surgeon was unable to remove and/or connect the inserter with the stem during surgery due to excess material remaining within the taper. Issue may lead to clinically significant extension of surgery to find a replacement.

Timeline

5 dated events

  1. Cleared FDA 510(k) K140390
  2. Cleared FDA 510(k) K193038
  3. Listed FDA GUDID 00887868506499
  4. Recall initiated FDA recalls Z-1403-2025
  5. Registered EUDAMED 889024-ZB001980-GY

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Comprehensive® Shoulder Instruments
Generic name
Medullary canal orthopaedic reamer, rigid
Device name
EX 4mm Comp ET Humeral Reamer
Model / Ref / Catalog
41-406804
Primary DI / UDI-DI
00887868506499
Basic UDI-DI
889024-ZB001980-GY
Direct marketing DI
00887868506499
510(k) Number
FDA product code
KWT, KWS, HSD, MBF
EMDN code
L091102 Orthopaedic prostheses reamers and burs, reusable
GMDN term
Medullary canal orthopaedic reamer, rigid
Device class
Class I EUDAMED
Class II GUDID
Regulation number
888.3650, 888.3660, 888.3690, 888.3670
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under ORTHOPAEDIC PROSTHESES REAMERS AND BURS, REUSABLE.

Other devices from Biomet Orthopedics, Inc.

See all devices from Biomet Orthopedics, Inc. →

Properties

  • Sterilise before use
  • Reusable
  • Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction)
  • Prescription use
  • Lot / batch number
Other properties (20, all answered No)