# Comprehensive® Shoulder System 113635

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/comprehensive-r-shoulder-system-113635>
- Manufacturer: [Biomet Orthopedics, Inc.](https://devicerts.com/manufacturers/biomet-orthopedics-inc) (United States)
- Device class: Class II (US FDA)
- FDA product code: HSD, KWS, MBF, KWT
- GMDN: Coated shoulder humeral stem prosthesis (39702)

## Registrations and authorizations

- **GUDID** · FDA 510(k) · United States · K193038 · decision 2020-10-28 · decision SESE · status: Active · from GUDID
- **GUDID** · GUDID listing · United States · UDI-DI 00887868267826 · listed 2019-08-30 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K060692 · decision 2006-05-30 · decision SESE · status: Active · from GUDID

## Recalls

- Z-1403-2025 · Class II · ongoing · initiated 2025-03-03: Five complaints received where surgeon was unable to remove and/or connect the inserter with the stem during surgery due to excess material remaining within the taper. Issue may lead to clinically significant extension of surgery to find a replacement.
- Z-1543-2020 · Class II · terminated · initiated 2020-02-17: A 15mm Shoulder Mini Humeral Stem was misidentified as a 9mm Shoulder Mini Humeral Stem.
- Z-0591-2019 · Class II · terminated · initiated 2018-10-10: Zimmer Biomet is conducting a lot specific medical device recall for two lots of the Orthopedic Salvage System (OSS) and the Comprehensive Shoulder System. The investigation determined that the Mini Humeral Stem is potentially labeled as the Bowed IM Stem lot. The associated risk of this product issue is a potential extension of surgery \<30 minutes if a replacement is readily available.
- Z-0980-2018 · Class II · terminated · initiated 2017-12-08: Zimmer Biomet is conducting a medical device recall for two lots of Comprehensive Humeral stems. The lots were commingled during the manufacturing process and were etched with incorrect lot numbers. The size difference between the two stem sizes is 1.1 inches. It is visually recognizable by the user that the box label does not match the contents of the box.
- Z-0979-2018 · Class II · terminated · initiated 2017-12-08: Zimmer Biomet is conducting a medical device recall for two lots of Comprehensive Humeral stems. The lots were commingled during the manufacturing process and were etched with incorrect lot numbers. The size difference between the two stem sizes is 1.1 inches. It is visually recognizable by the user that the box label does not match the contents of the box.
- Z-0299-2018 · Class II · terminated · initiated 2017-06-05: Possibility that the patient label inside the product box was incorrectly labeled. The outer box label and actual product are correctly identified but the internal patient label could be incorrect.
- Z-1755-2015 · Class III · terminated · initiated 2015-04-16: Biomet hip joint, knee joint and shoulder joint replacement components device labeling contains incorrect GTIN (Global Trade Identification Number) codes.

## Identity

- Trade name: Comprehensive® Shoulder System [FDA GUDID (AccessGUDID)]
- Generic name: Coated shoulder humeral stem prosthesis [FDA GUDID (AccessGUDID)]
- Model / Ref / Catalog: 113635 [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 00887868267826 [FDA GUDID (AccessGUDID)]
- 510(k) Number: K060692 [FDA GUDID (AccessGUDID)]; K193038 [FDA GUDID (AccessGUDID)]
- FDA product code: HSD [FDA GUDID (AccessGUDID)]; KWS [FDA GUDID (AccessGUDID)]; MBF [FDA GUDID (AccessGUDID)]; KWT [FDA GUDID (AccessGUDID)]
- GMDN term: Coated shoulder humeral stem prosthesis (39702) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 888.3690 [FDA GUDID (AccessGUDID)]; 888.3660 [FDA GUDID (AccessGUDID)]; 888.3670 [FDA GUDID (AccessGUDID)]; 888.3650 [FDA GUDID (AccessGUDID)]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Supplied sterile: Yes [FDA GUDID (AccessGUDID)]
- Single use: Yes [FDA GUDID (AccessGUDID)]
- Implantable: Yes [FDA GUDID (AccessGUDID)]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Expiration date: Yes [FDA GUDID (AccessGUDID)]
- Sterilise before use: No [FDA GUDID (AccessGUDID)]
- Contains latex: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Comprehensive® Shoulder System 113635, Biomet Orthopedics, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/comprehensive-r-shoulder-system-113635 (data as of 2026-11-21).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-21
- JSON: <https://devicerts.com/devices/comprehensive-r-shoulder-system-113635.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/comprehensive-r-shoulder-system-113635
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.