Comprehensive® Shoulder System 405315
Part of a family of 17 devices: see the family page
Ref 405315
Comprehensive Shoulder System 405315 is a humeral stem prosthesis trial (EU MDR Class IIa; FDA Class II) made by Biomet Orthopedics, Inc., registered in EUDAMED on 30 Oct 2026 (Basic UDI-DI 889024-ZB002006-EN), cleared under FDA 510(k) K193038 on 28 Oct 2020 (2 earlier submissions) and listed in FDA GUDID since 19 Mar 2022 (UDI-DI 00887868504501), active as of 7 Nov 2026. 22 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
1 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number889024-ZB002006-EN 00887868504501 | Date30 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00887868504501 | Date19 Mar 2022 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK193038 | Date28 Oct 2020 | StatusActive |
Official records
- EUDAMED public site 889024-ZB002006-EN
- AccessGUDID record 00887868504501
- FDA 510(k) database K193038
- FDA 510(k) database K080642
- FDA 510(k) database K060692
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI 889024-ZB002006-EN registered 30 Oct 2026 Active
- FDA 510(k) K193038 decided 28 Oct 2020 Active
- FDA GUDID UDI-DI 00887868504501 listed 19 Mar 2022 Listed
Recalls
-
- Ongoing Z-1403-2025
Five complaints received where surgeon was unable to remove and/or connect the inserter with the stem during surgery due to excess material remaining within the taper. Issue may lead to clinically significant extension of surgery to find a replacement.
-
- Terminated Z-2144-2020
Potential presence of elevated endotoxin levels that exceed the specification limit
-
- Terminated Z-1750-2020
There were unknown bioburden levels prior to sterilization, which may affect sterility of the product.
-
- Terminated Z-1543-2020
A 15mm Shoulder Mini Humeral Stem was misidentified as a 9mm Shoulder Mini Humeral Stem.
-
- Terminated Z-0591-2019
Zimmer Biomet is conducting a lot specific medical device recall for two lots of the Orthopedic Salvage System (OSS) and the Comprehensive Shoulder System. The investigation determined that the Mini Humeral Stem is potentially labeled as the Bowed IM Stem lot. The associated risk of this product issue is a potential extension of surgery <30 minutes if a replacement is readily available.
-
- Terminated Z-0980-2018
- Terminated Z-0979-2018
Zimmer Biomet is conducting a medical device recall for two lots of Comprehensive Humeral stems. The lots were commingled during the manufacturing process and were etched with incorrect lot numbers. The size difference between the two stem sizes is 1.1 inches. It is visually recognizable by the user that the box label does not match the contents of the box.
-
- Terminated Z-0299-2018
Possibility that the patient label inside the product box was incorrectly labeled. The outer box label and actual product are correctly identified but the internal patient label could be incorrect.
-
- Terminated Z-1859-2017
Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components.
-
- Terminated Z-1103-2017
Higher than anticipated rate of fracturing due to design. Risk of revision surgery due to fracturing.
-
- Terminated Z-1755-2015
Biomet hip joint, knee joint and shoulder joint replacement components device labeling contains incorrect GTIN (Global Trade Identification Number) codes.
-
- Terminated Z-1548-2013
Biomet has initiated this action following an investigation which identified that the slot on the resection guide is offset in the wrong direction. When the slot on the resection guide is offset in the wrong direction, the Steinman pin that is intended to hold the guide into place may not come into contact with the bone.
-
- Terminated Z-2548-2011
- Terminated Z-2547-2011
- Terminated Z-2550-2011
- Terminated Z-2546-2011
- Terminated Z-2542-2011
- Terminated Z-2545-2011
- Terminated Z-2541-2011
- Terminated Z-2549-2011
- Terminated Z-2544-2011
- Terminated Z-2543-2011
The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled.
-
- Terminated Z-0712-2011
- Terminated Z-0713-2011
The firm received complaints regarding fracturing of the device.
Timeline
- Recall initiated FDA recalls Z-0980-2018
- Recall initiated FDA recalls Z-0979-2018
- Recall initiated FDA recalls Z-0591-2019
- Recall initiated FDA recalls Z-1543-2020
- Recall initiated FDA recalls Z-1750-2020
- Recall initiated FDA recalls Z-2144-2020
- Cleared FDA 510(k) K193038
- Listed FDA GUDID 00887868504501
- Recall initiated FDA recalls Z-1403-2025
- Registered EUDAMED 889024-ZB002006-EN
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Comprehensive® Shoulder System
- Generic name
- Humeral stem prosthesis trial, reusable
- Device name
- Comp Micro Broach Provisional
- Model / Ref / Catalog
- 405315
- Primary DI / UDI-DI
- 00887868504501
- Basic UDI-DI
- 889024-ZB002006-EN
- FDA product code
- HSD, MBF, KWT, KWS, PAO
- EMDN code
- L091099 Osteosynthesis instruments, reusable - other
- GMDN term
- Humeral stem prosthesis trial, reusable
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 888.3690, 888.3670, 888.3650, 888.3660
- EU registration type
- Standard device
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under OSTEOSYNTHESIS INSTRUMENTS, REUSABLE - OTHER.
- ACUMED PLT-SLB10L by ACUMED LLC
- ELOS INSTRUMENTS SE203 by INTRAUMA SPA
- ACUMED CO-S2314-S by ACUMED LLC
- ROCCIA ACIF by Silony Medical GmbH
- Zimmer® Natural Nail® 02.60000.018 by Zimmer, Inc.
- Oyster ACIF Cage by Silony Medical GmbH
- CONMED GFT-SM by Conmed Corporation
- Trial Feeler Elevator 03.641.001 by Synthes GmbH
- NCB® 02.00024.353 by Zimmer, Inc.
- VIPER PRIME 286750041 by MEDOS INTERNATIONAL SARL