Skip to content

Comprehensive® SRS Instrument 405202

by Biomet Orthopedics, Inc.

Comprehensive® SRS Instrument 405202 is a Class II device made by Biomet Orthopedics, Inc., cleared under FDA 510(k) K111746 on 15 Dec 2011 (1 earlier submission) and listed in FDA GUDID since 23 Apr 2022 (UDI-DI 00887868504075), active as of 22 Oct 2026. 16 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

18 closed

Documents

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00887868504075 UDI-DI Date23 Apr 2022ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK111746 Date15 Dec 2011DecidedStatusActive

Official records

Across registries

2 registries list this device

  • FDA 510(k) K111746 decided 15 Dec 2011 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00887868504075 listed 23 Apr 2022 Listed

Recalls

18 recalls · FDA

    • Terminated Z-2144-2020 FDA Class II initiated 17 Apr 2020 on shared 510(k) K080642

    Potential presence of elevated endotoxin levels that exceed the specification limit

    • Terminated Z-1750-2020 FDA Class II initiated 13 Mar 2020 on shared 510(k) K080642

    There were unknown bioburden levels prior to sterilization, which may affect sterility of the product.

    • Terminated Z-1173-2018 FDA Class II initiated 28 Feb 2018

    During assembly, an SRS Humeral Distal Body implant failed to engage correctly at the point of reduction with a Discovery Elbow System Humeral Condyle. A mismatch between the screw holes in the Humeral Body & Elbow Condyle affects assembly during surgery. If the product has already been implanted, no action is required. The mismatch is estimated to prevent screw engagement in less than 1% of cases.

    • Terminated Z-1859-2017 FDA Class II initiated 17 Feb 2017

    Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components.

    • Terminated Z-1103-2017 FDA Class I initiated 20 Dec 2016

    Higher than anticipated rate of fracturing due to design. Risk of revision surgery due to fracturing.

    • Terminated Z-1548-2013 FDA Class II initiated 15 May 2013

    Biomet has initiated this action following an investigation which identified that the slot on the resection guide is offset in the wrong direction. When the slot on the resection guide is offset in the wrong direction, the Steinman pin that is intended to hold the guide into place may not come into contact with the bone.

  • 10 recalls, same reason

    • Terminated Z-2541-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2549-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2548-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2547-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2550-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2546-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2542-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2545-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2544-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2543-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011

    The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled.

  • 2 recalls, same reason

    • Terminated Z-0712-2011 FDA Unclassified (pre-2012) initiated 13 Sep 2010
    • Terminated Z-0713-2011 FDA Unclassified (pre-2012) initiated 13 Sep 2010

    The firm received complaints regarding fracturing of the device.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

21 dated events

  1. Recall initiated FDA recalls Z-2544-2011
  2. Recall initiated FDA recalls Z-2543-2011
  3. Cleared FDA 510(k) K111746
  4. Recall initiated FDA recalls Z-1548-2013
  5. Recall initiated FDA recalls Z-1103-2017
  6. Recall initiated FDA recalls Z-1859-2017
  7. Recall initiated FDA recalls Z-1173-2018
  8. Recall initiated FDA recalls Z-1750-2020
  9. Recall initiated FDA recalls Z-2144-2020
  10. Listed FDA GUDID 00887868504075

11 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Comprehensive® SRS Instrument
Generic name
Humeral stem prosthesis trial, reusable
Model / Ref / Catalog
405202
Primary DI / UDI-DI
00887868504075
510(k) Number
FDA product code
JDC, KWT, KWS, MBF, PAO
GMDN term
Humeral stem prosthesis trial, reusable
Device class
Class II
Regulation number
888.3150, 888.3650, 888.3660, 888.3670
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Other devices from Biomet Orthopedics, Inc.

See all devices from Biomet Orthopedics, Inc. →

Properties

  • Sterilise before use
  • Prescription use
  • Lot / batch number
Other properties (12, all answered No)