Comprehensive SRS 211228
Comprehensive SRS 211228 is a device of GMDN type partial shoulder prosthesis (FDA Class II) made by Biomet Orthopedics, Inc., cleared under FDA 510(k) K223631 on 12 Jul 2023 (2 earlier submissions) and listed in FDA GUDID since 24 Oct 2015 (UDI-DI 00880304507876), active as of 23 Oct 2026. One FDA recall is linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK223631 | Date12 Jul 2023 | StatusActive |
| United States | GUDID listing | Number00880304507876 | Date24 Oct 2015 | StatusListed |
Official records
- AccessGUDID record 00880304507876
- FDA 510(k) database K223631
- FDA 510(k) database K173411
- FDA 510(k) database K111746
From the FDA record
- MRI safety
- MR Conditional
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K223631 decided 12 Jul 2023 Active
- FDA GUDID UDI-DI 00880304507876 listed 24 Oct 2015 Listed
Recalls
-
- Terminated Z-1173-2018
During assembly, an SRS Humeral Distal Body implant failed to engage correctly at the point of reduction with a Discovery Elbow System Humeral Condyle. A mismatch between the screw holes in the Humeral Body & Elbow Condyle affects assembly during surgery. If the product has already been implanted, no action is required. The mismatch is estimated to prevent screw engagement in less than 1% of cases.
Timeline
- Cleared FDA 510(k) K111746
- Listed FDA GUDID 00880304507876
- Cleared FDA 510(k) K173411
- Recall initiated FDA recalls Z-1173-2018
- Cleared FDA 510(k) K223631
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Comprehensive SRS
- Generic name
- Partial shoulder prosthesis
- Model / Ref / Catalog
- 211228
- Primary DI / UDI-DI
- 00880304507876
- FDA product code
- KWT, KWS, JDC, MBF, PHX
- GMDN term
- Partial shoulder prosthesis
- Device class
- Class II
- Regulation number
- 888.3650, 888.3660, 888.3150, 888.3670
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Conditional
Similar devices
Other devices filed under FDA product code KWT (PROSTHESIS, SHOULDER, NON-CONSTRAINED, METAL/POLYMER CEMENTED).
- Humeral Cup Standard 312-0706 by FX SOLUTIONS
- SMR TT Hybrid Glenoid 1379.59.311 by Limacorporate
- NEER-III SOLID KEEL GLENOID RESURFACING PROSTHESIS by Kirschner Medical Corp.
- Alliance® SBGL4130 by Zimmer, Inc.
- Anatomical Shoulder™ Bigliani/Flatow® 01.04255.002 by Zimmer, Inc.
- TiN Coated Humeral Head 116-4300 by FX SOLUTIONS
- SMR Shoulder Humeral Head (CoCrMo) 1325.09.421 by Limacorporate
- TiN Coated Humeral Head by Fx Shoulder USA, Inc.
- SELECT(R) SHOULDER ALL-POLY GLENOID by Intermedics Orthopedics
- LINK Embrace Shoulder System 645-022/58 by WALDEMAR LINK GmbH & Co. KG