Conmed C2854
Ref C2854
Conmed C2854 is a tendon/ligament bone anchor (EU MDD Class IIb; FDA Class II; FDA product code HTN, Washer, Bolt Nut) made by Conmed Corporation, registered in EUDAMED on 19 Jun 2026 (Basic UDI-DI B-20845854019594), cleared under FDA 510(k) K954682 on 9 Feb 1996 and listed in FDA GUDID since 10 Dec 2015 (UDI-DI 20845854019594), active as of 24 Oct 2026.
Active
CE MDD 510(k)
Valid until
No date given
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-20845854019594 20845854019594 | Date19 Jun 2026 | StatusActive |
| United States | GUDID listing GUDID | Number20845854019594 | Date10 Dec 2015 | StatusListed |
| United States | FDA 510(k)SN GUDID | NumberK954682 | Date9 Feb 1996 | StatusActive |
Official records
- EUDAMED public site B-20845854019594
- AccessGUDID record 20845854019594
- FDA 510(k) database K954682
From the FDA record
- Device description
- CORTICAL SCREW, 4.5 X 54 MM
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI B-20845854019594 registered 19 Jun 2026 Active
- FDA 510(k) K954682 decided 9 Feb 1996 Active
- FDA GUDID UDI-DI 20845854019594 listed 10 Dec 2015 Listed
Timeline
- Cleared FDA 510(k) K954682
- Listed FDA GUDID 20845854019594
- Registered EUDAMED B-20845854019594
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Conmed
- Generic name
- Tendon/ligament bone anchor, non-bioabsorbable
- Device name
- Orthopedic, Implant, Non-absorbable, Interference Screw, Titanium, Knee and Shoulder, Cortical
- Model / Ref / Catalog
- C2854
- Primary DI / UDI-DI
- 20845854019594
- Basic UDI-DI
- B-20845854019594
- 510(k) Number
- FDA product code
- HTN
- EMDN code
- P09120601 Cortical screws
- GMDN term
- Tendon/ligament bone anchor, non-bioabsorbable
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 888.3030
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Belgium
- GUDID distribution status
- In Commercial Distribution
- Size
- Outer Diameter — 4.5 MillimeterLength — 54 Millimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under CORTICAL SCREWS.
- ACUMED CO-3400 by ACUMED LLC
- ACUMED 3051-25014-S by ACUMED LLC
- NCB® 02.02151.010 by Zimmer, Inc.
- LOQTEQ® SK 4526-30-2 by aap Implantate AG
- Traufix 154.30 by FIXIER SA DE CV
- TraumaOne SYSTEM 41-2016 by BIOMET MICROFIXATION, INC
- A.L.P.S.® 8512-35-065 851235065 by Biomet Orthopedics, Inc.
- NA SK 3514-65-2 by aap Implantate AG
- CHIMAERA Hip Fracture System 1 99-T93575 by ORTHOFIX SRL
- A.L.P.S.® 8512-35-038 851235038 by Biomet Orthopedics, Inc.