Conquest Series 0300034503
Ref 0300-034-503Model 08858250000308RJ
Conquest Series 0300034503 (0300-034-503) is a ligament reconstruction instrument set (EU MDR Class I; FDA Class I; FDA product code NBH, Accessories, arthroscopic) made by Stryker Corp., registered in EUDAMED on 6 Oct 2026 (Basic UDI-DI 08858250000308RJ) and listed in FDA GUDID since 3 Aug 2018 (UDI-DI 07613327053401), active as of 25 Oct 2026.
Active
CE MDR
Valid until
No date given
FDA recalls
Not checked
Documents
None linked in EUDAMED
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number08858250000308RJ 07613327053401 | Date6 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number07613327053401 | Date3 Aug 2018 | StatusListed |
Official records
- EUDAMED public site 08858250000308RJ
- AccessGUDID record 07613327053401
From the FDA record
- Device description
- Meniscal Crescent Punch, 30 Degrees Left
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Ethylene Oxide)
Across registries
- EUDAMED Basic UDI-DI 08858250000308RJ registered 6 Oct 2026 Active
- FDA GUDID UDI-DI 07613327053401 listed 3 Aug 2018 Listed
Timeline
- Listed FDA GUDID 07613327053401
- Registered EUDAMED 08858250000308RJ
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Conquest Series
- Generic name
- Ligament reconstruction instrument set, reusable
- Device name
- SMBU_TF10436_Punches for Reusable Surgical Instruments
- Model / Ref / Catalog
- 08858250000308RJ, 0300-034-503, 0300034503
- Primary DI / UDI-DI
- 07613327053401
- Basic UDI-DI
- 08858250000308RJ
- Direct marketing DI
- 07613327053401
- FDA product code
- NBH
- EMDN code
- L090999 Orthopaedic surgery cutting instruments, reusable - other
- GMDN term
- Ligament reconstruction instrument set, reusable
- Device class
- Class I
- Regulation number
- 888.1100
- EU registration type
- Standard device
- EU market of registration
- Ireland
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Ethylene Oxide
- Size
- Outer Diameter — 3.4 Millimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 08858250000308RJ 0300-034-503 | 0300034503 |
Similar devices in this category
Other devices filed under ORTHOPAEDIC SURGERY CUTTING INSTRUMENTS, REUSABLE - OTHER.
- NexGen® 00-5901-032-00 by Zimmer, Inc.
- Sayan 1041.77.003 by SAYAN TIBBI ALETLER PAZARLAMA SANAYI VE TICARET LIMITED SIRKETI
- NexGen® 5951-90 00-5951-090-00 by Zimmer, Inc.
- Gimmi KH.1910.24 by Gimmi GmbH
- Gimmi KH.1902.02 by Gimmi GmbH
- EXPEDIUM SPINE SYSTEM 279729910 by MEDOS INTERNATIONAL SARL
- Crossback Acetabular Reamer 79mm T17648 by Viant Medical, LLC
- Crossback Acetabular Reamer 44mm T17613 by Viant Medical, LLC
- AEGIS ANTERIOR LUMBAR PLATE 287110100 by MEDOS INTERNATIONAL SARL
- DIAM, Sicard Punch, Large CS001B0022 by Companion Spine France