Contec CMS9000
by Contec Medical Systems Co., Ltd.
Ref CMS9000
Contec CMS9000 is a general-purpose multi-parameter bedside monitor (EU MDD Class IIb; FDA Class II) made by Contec Medical Systems Co., Ltd., registered in EUDAMED on 7 Jul 2026 (Basic UDI-DI B-06945040100515), cleared under FDA 510(k) K101692 on 28 Jun 2011 and listed in FDA GUDID since 24 Sep 2016 (UDI-DI 06945040100515), active as of 24 Oct 2026. One FDA recall is linked to it.
Active
CE MDD 510(k)
Valid until
No date given
FDA recalls
1 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-06945040100515 06945040100515 | Date7 Jul 2026 | StatusActive |
| United States | GUDID listing GUDID | Number06945040100515 | Date24 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK101692 | Date28 Jun 2011 | StatusActive |
Official records
- EUDAMED public site B-06945040100515
- AccessGUDID record 06945040100515
- FDA 510(k) database K101692
From the FDA record
- Device description
- Patient Monitor
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI B-06945040100515 registered 7 Jul 2026 Active
- FDA 510(k) K101692 decided 28 Jun 2011 Active
- FDA GUDID UDI-DI 06945040100515 listed 24 Sep 2016 Listed
Recalls
-
- Ongoing Z-1764-2025
Patient monitor has nine identified cybersecurity vulnerabilities.
Timeline
- Cleared FDA 510(k) K101692
- Listed FDA GUDID 06945040100515
- Recall initiated FDA recalls Z-1764-2025
- Registered EUDAMED B-06945040100515
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Patient Monitor EUDAMEDContec GUDID
- Generic name
- General-purpose multi-parameter bedside monitor
- Model / reference
- CMS9000
- Primary DI / UDI-DI
- 06945040100515
- Basic UDI-DI
- B-06945040100515
- 510(k) Number
- FDA product code
- BZQ, DQA, DSK, DXN, DRT, MLD, DSI, MHX
- EMDN code
- Z1203020201 Multi–parameter patient bedside monitors
- GMDN term
- General-purpose multi-parameter bedside monitor
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 868.2375, 870.2700, 870.1110, 870.1130, 870.2300, 870.1025
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under MULTI–PARAMETER PATIENT BEDSIDE MONITORS.
- Patient Monitor by Shenzhen Creative Industry Co., Ltd.
- SAADAT 43525967 by Pooyandegan rah saadat
- Handheld monitor M860 by GUANGDONG BIOLIGHT MEDITECH CO., LTD
- Welch Allyn, Inc. 901060 68MXEX-B by Welch Allyn, Inc.
- Welch Allyn, Inc. 901028 85NXVE by Welch Allyn, Inc.
- uMEC7 Patient Monitor by Shenzhen Mindray Bio-Medical Electronics Co., Ltd.
- Patient Monitor Q3 by GUANGDONG BIOLIGHT MEDITECH CO., LTD
- Multi-parameter patient monitor Z120302 by Northern Meditec Limited
- Fetal Monitor F3 by Edan Instruments,Inc.
- uMEC6 Patient Monitor by Shenzhen Mindray Bio-Medical Electronics Co., Ltd.