Context Filter

by Geometric Data, Div. Smithkline Corp.

510(k) K791108

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK791108 Date17 Jul 1979ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
GKZ
Device Class
Class II
Regulation
21 CFR Part 864.5220
Advisory Committee
Hematology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Context Filter is a Differential Cell Counter, a Class II hematology device designed to separate and quantify blood cell types by size and density. It automates the differential analysis of white blood cells, distinguishing neutrophils, lymphocytes, monocytes, eosinophils, and basophils for diagnostic evaluation. The device operates by applying physical filtration principles to blood samples, enabling precise cell classification without manual intervention.

Supplied as a reusable instrument, the Context Filter is intended for use in clinical laboratories and hematology settings. It requires sterile blood samples and is regulated under FDA 510(k) clearance (K791108) with product code GKZ, adhering to the Traditional 510(k) review pathway. The device is not MRI-compatible and must be stored in accordance with manufacturer guidelines to maintain performance. No additional regulatory markings beyond the FDA clearance are specified.

Other devices from Geometric Data, Div. Smithkline Corp.

See all devices from Geometric Data, Div. Smithkline Corp. →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Context Filter used for in clinical settings?

    The Context Filter is a Differential Cell Counter designed to automate the separation and quantification of white blood cells by size and density. It distinguishes between neutrophils, lymphocytes, monocytes, eosinophils, and basophils, streamlining diagnostic evaluations in hematology labs. This eliminates the need for manual differential counting, improving efficiency and accuracy.

  • Is the Context Filter a single-use or reusable device?

    The Context Filter is supplied as a reusable instrument. It is intended for repeated use in clinical laboratories and hematology settings, provided it is maintained and stored according to the manufacturer’s guidelines to ensure consistent performance and sterility of blood samples.

  • What type of blood samples does the Context Filter require?

    The Context Filter requires sterile blood samples for operation. Sterility is critical to prevent contamination and ensure accurate cell classification, as the device relies on physical filtration principles to analyze the sample without manual intervention.

  • Does the Context Filter have any special storage or maintenance requirements?

    The Context Filter must be stored in accordance with the manufacturer’s guidelines to maintain its performance. While the device itself is reusable, proper storage conditions—such as cleanliness, protection from physical damage, and adherence to environmental controls—are essential to preserve functionality over time.

  • Is the Context Filter compatible with MRI environments?

    No, the Context Filter is explicitly stated as not MRI-compatible. If used in proximity to MRI machines, the device should be positioned outside the MRI scan area to avoid potential interference or safety risks.