Convex Probe MC10-3 A9E0
Ref MC10-3Model CONVEX PROBE MC10-3
Convex Probe MC10-3 A9E0 is an extracorporeal ultrasound imaging transducer (EU MDR Class IIa; FDA Class II; FDA product code ITX, Transducer, Ultrasonic, Diagnostic) made by Konica Minolta, Inc., registered in EUDAMED on 3 Jul 2026 (Basic UDI-DI 4560141920000658M), cleared under FDA 510(k) K162065 on 19 Oct 2016 and listed in FDA GUDID since 9 Nov 2016 (UDI-DI 04560141945111), withdrawn (EUDAMED), active (FDA 510(k)) as of 25 Oct 2026.
Active
Valid until
No expiry
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number4560141920000658M 04560141945111 | Date3 Jul 2026 | StatusWithdrawn |
| United States | GUDID listing GUDID | Number04560141945111 | Date9 Nov 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK162065 | Date19 Oct 2016 | StatusActive |
Official records
- EUDAMED public site 4560141920000658M
- AccessGUDID record 04560141945111
- FDA 510(k) database K162065
From the FDA record
- MRI safety
- MR Unsafe
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 4560141920000658M registered 3 Jul 2026 Withdrawn
- FDA 510(k) K162065 decided 19 Oct 2016 Active
- FDA GUDID UDI-DI 04560141945111 listed 9 Nov 2016 Listed
Recalls
-
- Terminated Z-1214-2018
There is a risk of circuit board breakage within the main housing of the AC Adapter unit. Smoke may be emitted from the AC Adapter as a direct result.
-
- Terminated Z-2769-2017
The Doppler velocity measurement on the Sonimage HS1 ultrasound system is not accurate.
Timeline
- Cleared FDA 510(k) K162065
- Listed FDA GUDID 04560141945111
- Recall initiated FDA recalls Z-2769-2017
- Recall initiated FDA recalls Z-1214-2018
- Registered EUDAMED 4560141920000658M
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Convex Probe MC10-3
- Generic name
- Extracorporeal ultrasound imaging transducer, hand-held
- Model / reference
- CONVEX PROBE MC10-3 EUDAMEDMC10-3 EUDAMEDA9E0 GUDID
- Primary DI / UDI-DI
- 04560141945111
- Basic UDI-DI
- 4560141920000658M
- Direct marketing DI
- 04560141945111
- 510(k) Number
- FDA product code
- ITX
- EMDN code
- Z110402010201 Curvilinear transcutaneous two–dimensional ultrasound probes (convex–array)
- GMDN term
- Extracorporeal ultrasound imaging transducer, hand-held
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 892.1570
- EU registration type
- Standard device
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Unsafe
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | CONVEX PROBE MC10-3 MC10-3 | A9E0 |
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under CURVILINEAR TRANSCUTANEOUS TWO–DIMENSIONAL ULTRASOUND PROBES (CONVEX–ARRAY).
- 8C-RS H40402LS by GE Healthcare Japan Corporation
- C11xp/8-5 MHz P14564-21A by Fujifilm Sonosite, Inc.
- ICTxp/9-5 MHz P14562-22A by Fujifilm Sonosite, Inc.
- 9C2 Transducer 9002 by BK MEDICAL APS
- GP-C01 99-7903-00 by Interson Corporation
- 11M2 Transducer 11653755 by SIEMENS MEDICAL SOLUTIONS USA, INC.
- C25P 04573596211366 by FUJIFILM CORPORATION
- C5-2 Transducer 11003875 by SIEMENS MEDICAL SOLUTIONS USA, INC.
- CA421 9600154000 by Esaote S.p.A.
- SC3421 122000400 by Esaote S.p.A.