Coratomic Model OVALITH-920BP
by Corptomic
510(k) K811768
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK811768 | Date20 Jul 1981 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DXY
- Device Class
- Class III
- Regulation
- 21 CFR Part 870.3610
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
The Coratomic Model Ovalith-920BP is an implantable pacemaker pulse-generator, designed to regulate cardiac rhythm by delivering electrical impulses to the heart when native conduction fails. This device is classified as a Class III medical device under FDA regulations, reflecting its role in life-sustaining or life-supporting functions.
The Ovalith-920BP is intended for surgical implantation and is supplied sterile for single-use. It is regulated under FDA 510(k) clearance (K811768) and falls under the device classification DXY, with a regulatory number of 870.3610. Storage and handling must comply with sterile medical device protocols to ensure proper functionality and patient safety.
Questions
AI-generated answers, 18 Sep 2026
What is the primary purpose of the Coratomic Model Ovalith-920BP and how does it function in the body?
The Coratomic Model Ovalith-920BP is an implantable pacemaker pulse-generator designed to regulate cardiac rhythm by delivering controlled electrical impulses to the heart when the body’s natural conduction system fails. It is intended for patients experiencing bradycardia or other conduction disorders, ensuring consistent heartbeats to maintain proper cardiac function.
Is the Coratomic Model Ovalith-920BP intended for single-use or can it be reused after implantation?
The device is supplied sterile and explicitly labeled for single-use only. Reuse is not recommended or supported by the manufacturer, as it could compromise sterility, functionality, and patient safety.
How should the Coratomic Model Ovalith-920BP be stored to maintain its integrity before use?
Since the device is sterile and intended for surgical implantation, it must be stored according to sterile medical device protocols. This includes keeping it in its original packaging, protected from contamination, and adhering to manufacturer guidelines to preserve functionality and sterility until use.
What regulatory pathway was followed for the FDA clearance of this device, and what does that mean for its use?
The Coratomic Model Ovalith-920BP received FDA clearance through a Traditional 510(k) process (K811768), with a decision code of SESE (Substantially Equivalent) under the Cardiovascular (CV) Advisory Committee. This means the FDA determined it is comparable to a legally marketed predicate device, ensuring it meets safety and effectiveness standards for implantable pacemaker pulse-generators.