Cordisnhyperion Hemoglobin A1 Test Sys

by Cordis Corp.

510(k) K812242

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK812242 Date9 Sep 1981ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
LCP
Device class
Class II
Regulation
21 CFR Part 864.7470
Advisory committee
Hematology
FDA decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Cordis Hyperion Hemoglobin A1 Test System is an assay device designed to measure glycosylated hemoglobin (HbA1c) levels in blood samples. HbA1c testing provides a long-term indicator of blood glucose control, aiding in the diagnosis and management of diabetes. This system quantifies the proportion of hemoglobin bound to glucose, reflecting average blood sugar levels over the preceding two to three months. It is classified as a Class II medical device under FDA regulations, ensuring compliance with stringent performance and safety standards.

This system is intended for use in clinical laboratories and healthcare settings by trained personnel. It operates as a single-use diagnostic tool, requiring no sterilization between tests. The device is regulated under FDA 510(k) clearance (K812242) and falls under the Assay, Glycosylated Hemoglobin product code (LCP). Supplied as a ready-to-use kit, it adheres to regulatory requirements outlined in 21 CFR 864.7470. No MRI safety or reusable components are specified in the device data.

Other devices from Cordis US Corp.

See all devices from Cordis US Corp. →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Cordis Hyperion Hemoglobin A1 Test System used for?

    The Cordis Hyperion Hemoglobin A1 Test System measures glycosylated hemoglobin (HbA1c) levels in blood samples. HbA1c provides a long-term average of blood glucose control over the preceding two to three months, which is critical for diagnosing and managing diabetes. This helps clinicians assess how well a patient’s blood sugar has been controlled over time, guiding treatment adjustments.

  • How is the Cordis Hyperion HbA1c Test System supplied?

    The system is supplied as a ready-to-use kit, designed for single-use only. Each kit contains all necessary components for performing one HbA1c test, eliminating the need for sterilization or preparation between uses. This ensures consistency and reduces the risk of cross-contamination in clinical settings.

  • Is the Cordis Hyperion HbA1c Test System reusable or single-use?

    The Cordis Hyperion HbA1c Test System is explicitly designed for single-use only. This design choice simplifies workflows in clinical laboratories by removing the need for cleaning, sterilization, or reprocessing between tests. Single-use devices also help maintain accuracy and reliability, as they are not subject to wear or degradation from repeated use.

  • What regulatory approval does the Cordis Hyperion HbA1c Test System hold?

    The Cordis Hyperion Hemoglobin A1 Test System holds FDA 510(k) clearance under the product code LCP (Assay, Glycosylated Hemoglobin). It is classified as a Class II medical device, adhering to stringent regulatory standards for performance, safety, and accuracy. The clearance number is K812242, and it complies with regulatory requirements outlined in 21 CFR 864.7470.

  • Does the Cordis Hyperion HbA1c Test System require any special storage conditions?

    While the device data does not specify exact storage conditions, most single-use assay systems like this are typically stored in a clean, dry environment protected from extreme temperatures and direct light. It is essential to follow the manufacturer’s instructions provided in the kit for optimal performance and shelf life. Proper storage ensures the accuracy and reliability of the test results.