CorVocet™ 00884450476383
by Merit Medical Systems, Inc.
Ref CORCA1810SB/BModel Corvocet Biopsy System, Achieve Biopsy System, Pink Achieve Biopsy System
CorVocet 00884450476383 (CORCA1810SB/B) is a soft-tissue biopsy procedure kit (EU MDD Class IIa; FDA Class II; FDA product code KNW, Instrument, Biopsy) made by Merit Medical Systems, Inc., registered in EUDAMED on 2 Nov 2026 (Basic UDI-DI B-00884450476383) and listed in FDA GUDID since 23 Nov 2020 (UDI-DI 00884450476383), active as of 7 Nov 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
1 ongoingDocuments
None linked in EUDAMED
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00884450476383 00884450476383 | Date2 Nov 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00884450476383 | Date23 Nov 2020 | StatusListed |
Official records
- EUDAMED public site B-00884450476383
- AccessGUDID record 00884450476383
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI B-00884450476383 registered 2 Nov 2026 Active
- FDA GUDID UDI-DI 00884450476383 listed 23 Nov 2020 Listed
Recalls
-
- Ongoing Z-0137-2023
Biopsy Systems have components that are misaligned due to an issue with the manufacturing assembly equipment, which may lead to the needle ejecting when triggered outside the body, which may result in user or patient needle stick injury.
Timeline
- Listed FDA GUDID 00884450476383
- Recall initiated FDA recalls Z-0137-2023
- Registered EUDAMED B-00884450476383
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- CorVocet™
- Generic name
- Soft-tissue biopsy procedure kit, non-medicated
- Device name
- Automatic Biopsy System
- Model / Ref / Catalog
- Corvocet Biopsy System, Achieve Biopsy System, Pink Achieve Biopsy System, CORCA1810SB/B, 00884450476383
- Primary DI / UDI-DI
- 00884450476383
- Basic UDI-DI
- B-00884450476383
- FDA product code
- KNW
- EMDN code
- A010299 Biopsy needles and kits - other
- GMDN term
- Soft-tissue biopsy procedure kit, non-medicated
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 876.1075
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | Corvocet Biopsy System, Achieve Biopsy System, Pink Achieve Biopsy System CORCA1810SB/B | 00884450476383 |
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under BIOPSY NEEDLES AND KITS - OTHER.
- Chiba Biopsy Needle DCHN-20-20.0-U by COOK INCORPORATED
- Cook G06987 DCHN-21-65.5-U by COOK INCORPORATED
- MicroFrance® 7778K1 by Integra Microfrance
- Integra® MicroFrance® CEV60-120 by Integra Microfrance
- Pro-Mag™ Ultra Automatic Biopsy Instrument 7675 by Argon Medical Devices, Inc.
- Co-Axial Introducer Needle MCXS1609LXM by Argon Medical Devices, Inc.
- Expect™ M00558730 by Boston Scientific
- BRAINPRO 41778C by Pajunk GmbH Medizintechnologie
- ATEC Sapphire 200 by Hologic