Coulter Gen-S System

by Coulter Corp. 510(k)

Active United States

510(k) K962988

Regulatory status

as of 29 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK962988 Date30 Oct 1996ClearedStatusActive

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Recalls

4 recalls · FDA

    • Terminated Z-1956-2011 FDA Unclassified (pre-2012) initiated 31 Jan 2011

    This recall was initiated because Beckman Coulter identified a problem with some date fields that are transmitted to the Laboratory Information System (LIS). Starting Jan 1, 2011, the date fields will transmit as a blank field to the LIS if the year is greater than 2010. The following dates are affected: Run date, Control expiration date, Date of birth (For individuals born in 2011 or later), a

    • Terminated Z-0315-2008 FDA Unclassified (pre-2012) initiated 18 Apr 2007

    Patient Mis-identification can occur: 1)- When a positive identifier (Sample ID or Cassette/Position) is manually edited to a positive identifier that is already in the To Do list. The workstation will accept the entry and no error message will be generated, creating 2 samples with the identical positive identifier. 2)- When manually entering a Patient ID, if a blank space is entered between th

    • Terminated Z-0475-06 FDA Unclassified (pre-2012) initiated 15 Dec 2005 on shared 510(k) K962988

    There is a risk of sample misidentification when processing samples in the Manual aspiration mode.

    • Terminated Z-0571-03 FDA Unclassified (pre-2012) initiated 10 Dec 2002 on shared 510(k) K962988

    Device design allows for cross contamination issue to occur, possibly affecting assays and results reports.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Specification

510(k)

510(k) Number
FDA Product Code
GKL
Device Class
Class II
Regulation
21 CFR Part 864.5200
Advisory Committee
Hematology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 6 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Coulter Gen-S System is an automated hematology analyzer that performs quantitative cell counting, leukocyte differential counting, and reticulocyte analysis for in‑vitro diagnostic use in clinical laboratories. It functions as an automated particle counter for blood samples, providing rapid and reproducible hematology results.

The system is classified as a Class II medical device and received FDA 510(k) clearance (K962988) as a substantially equivalent hematology counter. It is supplied by Coulter Corp. in Miami, FL, and is identified by product code GKL. The device is intended for use in clinical laboratory settings and is regulated under the Hematology advisory committee.

Other devices from Coulter Corp.

See all devices from Coulter Corp. →

Questions

AI-generated answers, 6 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of hematology measurements does the Coulter Gen‑S System perform?

    The system conducts quantitative cell counting, leukocyte differential counting, and reticulocyte analysis. By integrating these functions, it delivers a comprehensive blood profile from a single sample, which streamlines workflow and reduces the need for multiple instruments in a clinical laboratory.

  • Is the Coulter Gen‑S System supplied as a single unit or in multiple components?

    It is supplied as a complete, integrated analyzer by Coulter Corp. in Miami, FL. The package includes the hardware, software, and necessary accessories for operation, so laboratories receive a ready‑to‑use system without having to assemble separate modules.

  • What is the regulatory classification and clearance pathway for this device?

    The Gen‑S System is classified as a Class II medical device and received FDA 510(k) clearance (K962988) as a substantially equivalent hematology counter. This clearance indicates that the device meets the safety and effectiveness standards required for in‑vitro diagnostic use in the United States.

  • Can the Coulter Gen‑S System be used for point‑of‑care testing or is it limited to central labs?

    The device is intended for use in clinical laboratory settings, not for point‑of‑care environments. Its design, throughput, and integration with laboratory information systems make it suitable for centralized testing rather than bedside or bedside‑adjacent applications.

  • How does the system ensure reproducible results across multiple runs?

    Automation of sample handling, standardized reagent delivery, and built‑in quality‑control algorithms allow the Gen‑S System to produce rapid and reproducible hematology results. Consistent particle counting and differential analysis reduce operator variability and support reliable longitudinal patient monitoring.