Coulter Lh 500 Hematology Analyzer

by Beckman Coulter, Inc.

510(k) K032000

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

9 closed

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Abbreviated NumberK032000 Date13 Aug 2003ClearedStatusActive

Recalls

9 recalls · FDA

    • Terminated Z-1243-2012 FDA Unclassified (pre-2012) initiated 1 Dec 2011

    The recall was initiated because Beckman Coulter has confirmed that the Auto Stop and Auto Transmit features for Quality Control become disabled after scanning assay values from Coulter 5C and Retic-C Cell Controls assay sheets using the 2D Barcode scanner.

    • Terminated Z-0599-2012 FDA Unclassified (pre-2012) initiated 13 Oct 2011

    The recall was initiated because Beckman has identified a problem with Integrated Circuit chips used in different boards throughout the analyzer.

    • Terminated Z-2042-2011 FDA Unclassified (pre-2012) initiated 2 Mar 2011

    The recall was initiated because Beckman Coulter has identified a problem with Integrated Circuit Chips used in different boards throughout the Beckman Coulter LH500/HmX/HmX Autoloader Hematology analyzer.

    • Terminated Z-1955-2011 FDA Unclassified (pre-2012) initiated 31 Jan 2011

    This recall was initiated because Beckman Coulter identified a problem with some date fields that are transmitted to the Laboratory Information System (LIS). Starting Jan 1, 2011, the date fields will transmit as a blank field to the LIS if the year is greater than 2010. The following dates are affected: Run date, Control expiration date, Date of birth (For individuals born in 2011 or later), a

    • Terminated Z-2337-2010 FDA Unclassified (pre-2012) initiated 12 Feb 2010

    The recall was initiated after Beckman Coulter identified four (4) issues with the COULTER LH 500 Series System and the Unicel DxH 800 Coulter Cellular Analysis System: Issue 1: There is a potential for misidentification to occur when the system is configured in languages other than English or Chinese. The characters #,@,[,\,],`,{,|,}, or ~ are substituted or omitted in other languages. The issu

    • Terminated Z-1657-2010 FDA Unclassified (pre-2012) initiated 4 Feb 2010

    Issue 1: The system will substitute or omit the characters # @ [\] ' {I) when the system is configured in a language other than English or Chinese. Example: Using the character @, a substitution in the string '123@456' would result in '123#456' and an omission would result in '123456' Issue 2: The system will omit the character ~ regardless of language. Impact: There is a potential for Specimen

    • Terminated Z-0314-2008 FDA Unclassified (pre-2012) initiated 18 Apr 2007

    Patient Mis-identification can occur: 1)- When a positive identifier (Sample ID or Cassette/Position) is manually edited to a positive identifier that is already in the To Do list. The workstation will accept the entry and no error message will be generated, creating 2 samples with the identical positive identifier. 2)- When manually entering a Patient ID, if a blank space is entered between th

    • Terminated Z-1245-06 FDA Unclassified (pre-2012) initiated 17 Apr 2006 on shared 510(k) K032000

    Beckman has confirmed that erroneous results could be reported when the workstation database crashes.

    • Terminated Z-1433-04 FDA Unclassified (pre-2012) initiated 12 Aug 2004

    Beckman Coulter has confirmed an issue associated with the predilute mode of the COULTER LH 500 Hematology Analyzer. The workstation may display, transmit, and / or print an erroneous result or an incorrect dilution factor with a predilute sample result.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
GKZ
Device Class
Class II
Regulation
21 CFR Part 864.5220
Advisory Committee
Hematology
FDA Decision
SESE Substantially Equivalent

Other devices from Beckman Coulter, Inc.

See all devices from Beckman Coulter, Inc. →