Coulter LH 780 Hematology Analyzer
510(k) K061616
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK061616 | Date4 Oct 2006 | StatusActive |
Recalls
-
- Terminated Z-2481-2015
- Terminated Z-2480-2015
Beckman Coulter is recalling the LH 750 and LH780 Hematology Systems because the use of the diluent lots may eventually result in a compromised Hgb cuvette.
-
- Terminated Z-0471-2014
Beckman Coulter is recalling the LH 750 and LH 780 Hematology Systems because the optical degradation may potentially cause a delay in reporting results for nucleated red blood cells (nRBC), white blood cell differential and/or reticulocytes.
-
- Terminated Z-0113-2014
The check valves may fail on the Coulter LH 750 Hematology Analyzer (PN 6605632 and A85570) and Coulter LH 780 Hematology Analyzer (PN 723585 and A90728). A failure may result in an air or liquid leak at the connection to the Vacuum Overflow Tank waste line or at the Backwash Tank drain line.
-
- Terminated Z-1241-2012
The recall was initiated because Beckman Coulter has confirmed that the Auto Stop and Auto Transmit features for Quality Control become disabled after scanning assay values from Coulter 5C and Retic-C Cell Controls assay sheets using the 2D Barcode scanner.
-
- Terminated Z-1954-2011
This recall was initiated because Beckman Coulter identified a problem with some date fields that are transmitted to the Laboratory Information System (LIS). Starting Jan 1, 2011, the date fields will transmit as a blank field to the LIS if the year is greater than 2010. The following dates are affected: Run date, Control expiration date, Date of birth (For individuals born in 2011 or later), a
-
- Terminated Z-0313-2008
Patient Mis-identification can occur: 1)- When a positive identifier (Sample ID or Cassette/Position) is manually edited to a positive identifier that is already in the To Do list. The workstation will accept the entry and no error message will be generated, creating 2 samples with the identical positive identifier. 2)- When manually entering a Patient ID, if a blank space is entered between th
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- GKZ
- Device Class
- Class II
- Regulation
- 21 CFR Part 864.5220
- Advisory Committee
- Hematology
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 19 Sep 2026
The Coulter LH 780 Hematology Analyzer is a Counter, Differential Cell device designed for automated hematological analysis. It performs complete blood counts, including red blood cell, white blood cell, and platelet measurements, with integrated nucleated red blood cell (NRBC) enumeration for precise differential analysis.
This analyzer is intended for use in clinical laboratories and is supplied as a reusable, non-sterile instrument. It operates under FDA 510(k) clearance (K061616) as substantially equivalent to predicate devices, adhering to regulatory standards for hematology testing. The device requires proper calibration, maintenance, and storage as per manufacturer guidelines to ensure accurate and reliable performance.