Crank Frame Retractor
510(k) K882071
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK882071 | Date10 Jun 1988 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- GZT
- Device Class
- Class II
- Regulation
- 21 CFR Part 882.4800
- Advisory Committee
- Neurology
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
The Crank Frame Retractor is a self-retaining neurosurgical retractor designed for spinal procedures. It provides controlled exposure of the spine by maintaining retraction with a crank mechanism, ensuring stable access during surgery. This device is classified as a Class II medical device under FDA regulations and is intended for use in neurosurgical settings where precise retraction is required.
The Crank Frame Retractor is supplied as a reusable device and is latex-free. It is intended for use in sterile environments, such as operating rooms, and is regulated under FDA 510(k) clearance (K882071). The device adheres to special controls for Class II retractors and is authorized for use in neurosurgery as specified by the product code GZT (Retractor, Self-Retaining, For Neurosurgery).
Other devices from Karlin Technology, Inc.
Questions
AI-generated answers, 1 Oct 2026
What is the Crank Frame Retractor used for?
The Crank Frame Retractor is designed specifically for neurosurgical procedures to provide controlled exposure of the spine. Its crank mechanism allows surgeons to maintain stable retraction, ensuring consistent access during delicate spinal operations where precision is critical.
Is the Crank Frame Retractor reusable or single-use?
The Crank Frame Retractor is supplied as a reusable device. This design choice supports cost efficiency and sustainability while maintaining the high standards required for sterile neurosurgical environments.
How is the sterility of the Crank Frame Retractor ensured?
The device is intended for use in sterile environments, such as operating rooms, where proper sterilization protocols must be followed. While the manufacturer does not specify sterilization methods in the provided data, reusable medical devices like this typically undergo rigorous cleaning and sterilization processes (e.g., autoclaving or chemical sterilization) between uses to ensure safety and compliance with medical standards.
What regulatory approval does the Crank Frame Retractor hold?
The Crank Frame Retractor holds FDA 510(k) clearance under the reference number K882071. This clearance confirms that the device meets FDA requirements for safety and effectiveness as a Class II medical device, specifically for use as a self-retaining retractor in neurosurgery.
Are there different sizes or models of the Crank Frame Retractor?
The provided data does not specify distinct sizes or model variations for the Crank Frame Retractor. However, retractors like this often come in multiple sizes to accommodate different patient anatomies or surgical needs. For precise sizing information, consulting the manufacturer’s technical documentation or contacting Karlin Technology directly would be recommended.