D-10 220-0149
D-10 220-0149 (2200149) is a Class II device made by Bio-Rad Laboratories, cleared under FDA 510(k) K041444 on 9 Jun 2004 (1 earlier submission) and listed in FDA GUDID since 12 Sep 2016 (UDI-DI 00847817003417), active as of 23 Oct 2026. 7 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00847817003417 | Date12 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK041444 | Date9 Jun 2004 | StatusActive |
Official records
- AccessGUDID record 00847817003417
- FDA 510(k) database K041444
- FDA 510(k) database K031043
Across registries
- FDA 510(k) K041444 decided 9 Jun 2004 Active
- FDA GUDID UDI-DI 00847817003417 listed 12 Sep 2016 Listed
Recalls
-
- Terminated Z-1299-2014
On a rare occasion the D-10 software might generate an extra result by duplicating the result form the previous sample and the Sample ID/Injection number from the next sample.
-
- Terminated Z-0965-2014
D-10 A1c Dual Program Floppy was programmed incorrectly and cartridge injections counts are not being updated correctly when switching between the D-10 Dual Short Program and Extended Program on the D-10 Hemoglobin Testing System.
-
- Terminated Z-0018-2012
- Terminated Z-0017-2012
- Terminated Z-0019-2012
A previous recall related to reports of calibration failure and late retention times using Elution Buffer led to an examination of other buffers manufactured during the same time period and a decision was made to field correct these products until a definitive root cause and corrective action have been found and implemented.
-
- Terminated Z-2889-2011
Reports of calibration failure and late retention time using Elution Buffer AA10434 and AA10435.
-
- Terminated Z-1969-2011
The firm discovered that the Update Kit Floppy Diskette included in the reorder pack was mislabeled with an incorrect Lot Number for the Calibrator/Diluent Set as: S01819; The correct Lot Number for the Calibrator/Diluent Set is: S01704.
-
- Terminated Z-0376-2007
The Diluent in the D-10 Dual Program Calibrator reorder packs is defective, and can cause early calibration failure or elevated control and sample recovery results.
Timeline
- Cleared FDA 510(k) K041444
- Recall initiated FDA recalls Z-0376-2007
- Recall initiated FDA recalls Z-1969-2011
- Recall initiated FDA recalls Z-2889-2011
- Recall initiated FDA recalls Z-0018-2012
- Recall initiated FDA recalls Z-0017-2012
- Recall initiated FDA recalls Z-0019-2012
- Recall initiated FDA recalls Z-0965-2014
- Recall initiated FDA recalls Z-1299-2014
- Listed FDA GUDID 00847817003417
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- D-10
- Generic name
- Haemoglobin A2 (HbA2) IVD, reagent
- Model / Ref / Catalog
- 220-0149, 2200149
- Primary DI / UDI-DI
- 00847817003417
- FDA product code
- LCP
- GMDN term
- Haemoglobin A2 (HbA2) IVD, reagent
- Device class
- Class II
- Regulation number
- 864.7470
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code LCP (ASSAY, GLYCOSYLATED HEMOGLOBIN).
- PRIMUS MODEL CLC 330 by Primus Corp.
- VARIANT II HEMOGLOBIN A1C PROGRAM WITH MODELS 270-2101NU by Bio-Rad Laboratories, Inc.
- ADVIA CHEMISTRY FRUCTOSAMINE ASSAY, ADVIA CHEMISTRY FRUCTOSAMINE CALIBRATOR by Siemens Healthcare Diagnostics
- LABILE LYSING REAGENT by Helena Laboratories, Corp.
- GLYCOHEMOGLOBIN by Macomb Chemical Co.
- ORTHO* BI-LEVEL ASSAYED GLYCOH. CONTR. S by Ortho Diagnostic Systems, Inc.
- CLP GLYCOSYLATED HEMOGLOBIN CONTROL-NR by Creative Laboratory Products, Inc.
- COLUMNMATE II GHB AFFINITY REGENERABLE COLUMN by Helena Laboratories, Corp.
- PRIMUS LIQUID CONTROL FOR GHB/ALC LEVEL I AND LEVEL II by Primus Corp.
- HEMOGLOBIN ALC (HBA1C) & TOTAL ASSAYS FOR THE TECHNICON RA/OPERA SYSTEMS IN-VITRO DIAGNOSTIC SYSTEMS by Bayer Corp.