- Manufacturer: [Medicalgorithmics S.A.](https://devicerts.com/manufacturers/medicalgorithmics-s-a) (FDA registration: United States)
- Device class: Class IIa (EU MDR); Class II (US FDA)
- FDA product code: DQK, DPS, QYX
- EMDN: Z129092 VARIOUS INSTRUMENTS FOR FUNCTIONAL EXPLORATION AND THERAPEUTIC INTERVENTIONS - MEDICAL DEVICE SOFTWARE
- GMDN: Cardiopulmonary physiological parameter analysis software, professional-only (47699)

## Overview

*AI-generated summary, 2026-09-18. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

DeepRhythmAI is a set of deep learning-based algorithms for automated analysis of electrocardiogram (ECG) data, designed to detect and classify cardiac arrhythmias. It leverages advanced machine learning techniques, including convolutional neural networks and transformer models, to enhance diagnostic accuracy and efficiency in cardiac rhythm assessment.

DeepRhythmAI is supplied as a cloud-based software solution, intended for integration with third-party ECG devices and software platforms. It is classified as substantially equivalent under FDA 510(k) clearance (K253141) and meets MDR requirements, with no third-party involvement in its regulatory submission. The system is not single-use or reusable but operates as a standalone analytical tool, requiring no physical storage or sterilisation.

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 590302156DRAI23K · UDI-DI 05903021560742 · registered 2026-05-08 · status: Withdrawn
- **510(k)** · FDA 510(k) · United States · K253141 · decision 2025-12-11 · decision SESE · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 05903021560742 · listed 2025-06-06 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K250932 · decision 2025-05-27 · decision SESE · status: Active · from GUDID

## Recalls

No recall on record.

## Identity

- Generic name: Cardiopulmonary physiological parameter analysis software, professional-only [FDA GUDID (AccessGUDID)]
- Model / reference: 05903021560742 [EUDAMED]; Type: DRAI [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 05903021560742 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 590302156DRAI23K [EUDAMED]
- 510(k) Number: K253141 [FDA 510(k), FDA GUDID (AccessGUDID)]; K250932 [FDA GUDID (AccessGUDID)]
- FDA product code: DQK [FDA 510(k), FDA GUDID (AccessGUDID)]; DPS [FDA GUDID (AccessGUDID)]; QYX [FDA GUDID (AccessGUDID)]
- EMDN code: Z129092 [EUDAMED]
- GMDN term: Cardiopulmonary physiological parameter analysis software, professional-only (47699) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class IIa [EUDAMED]; Class II [FDA 510(k), FDA GUDID (AccessGUDID)]
- Regulation: 21 CFR Part 870.1425 [FDA 510(k), FDA GUDID (AccessGUDID)]; 870.2340 [FDA GUDID (AccessGUDID)]; 870.1025 [FDA GUDID (AccessGUDID)]
- Special device type: Software [EUDAMED]
- EU registration type: Standard device [EUDAMED]
- Advisory committee: Cardiovascular [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Manufacturing date: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: DeepRhythmAI, Medicalgorithmics S.A. deviCERTS medical device catalogue. https://devicerts.com/devices/deeprhythmai-dqk (data as of 2026-11-21).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-21
- JSON: <https://devicerts.com/devices/deeprhythmai-dqk.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/deeprhythmai-dqk
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.