Skip to content

Defibrillator Analyzer - DA-2006P

by Bc Group International, Inc.

510(k) K110192

Defibrillator Analyzer - DA-2006P is a medical device (FDA Class II; FDA product code DRL, Tester, Defibrillator) made by Bc Group International, Inc., cleared under FDA 510(k) K110192 on 8 Feb 2011, active as of 10 Oct 2026. One FDA recall is linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

1 closed

Documents

Trust

Unverified

Source FDA 510(k), synced 10 Oct 2026.

Regulatory status

as of registry sync 10 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK110192 Date8 Feb 2011ClearedStatusActive

Official records

From the FDA record

Received by the FDA
24 Jan 2011
FDA decision
8 Feb 2011 (Substantially Equivalent)
FDA review time
15 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K110192 (openFDA), as read on 10 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

1 recall · FDA

    • Terminated Z-0457-2016 FDA Class III initiated 28 Oct 2015

    Device is not functioning as intended: Two wires running to the ECG distribution circuit board are reversed resulting in inverted waveforms.

Timeline

2 dated events

  1. Cleared FDA 510(k) K110192
  2. Recall initiated FDA recalls Z-0457-2016

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
DRL
Device class
Class II
Regulation
21 CFR Part 870.5325
Advisory committee
Cardiovascular
FDA decision
SESE Substantially Equivalent

Devices cleared under K110192

4 devices · FDA GUDID

Devices that FDA's GUDID lists as cleared or approved under this submission number. One submission usually covers a whole product family, so the sizes and models are listed here once.

Devices cleared under K110192
UDI-DISize and differences
BC Biomedical Defibrillator Analyzer DA-2006
BC GROUP INTERNATIONAL, INC.
DA-2006 / DA-200600863313000309 —On the market
BC Biomedical Defibrillator Analyzer DA-2006P
BC GROUP INTERNATIONAL, INC.
DA-2006P / DA-2006P00863313000316 —On the market
Gossen Metrawatt SECULIFE DF Base
BC GROUP INTERNATIONAL, INC.
M695Q / DF Base00863313000354 —On the market
Gossen Metrawatt SECULIFE DF+
BC GROUP INTERNATIONAL, INC.
M695P / DF+00863313000347 —On the market

Similar devices

Other devices filed under FDA product code DRL (Tester, Defibrillator).

Other devices from Bc Group International, Inc.

See all devices from Bc Group International, Inc. →