# Definium Tempo Pro

> Active: European Union. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/definium-tempo-pro-b2402cab>
- Manufacturer: [GE HUALUN MEDICAL SYSTEMS CO. Ltd](https://devicerts.com/manufacturers/ge-hualun-medical-systems-co-ltd) (China)
- Device class: Class IIb (EU MDR); Class II (US FDA)
- FDA product code: MQB, IZF, KPR
- EMDN: Z11031101 MULTIFUNCTIONAL SYSTEMS FOR DIRECT DIGITAL RADIOLOGY
- GMDN: Stationary basic diagnostic x-ray system, digital (37645)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 8406821BUG00193HJ · UDI-DI 00195278070265 · registered 2022-01-18 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 00195278070265 · listed 2020-11-24 · status: Listed (GUDID: in commercial distribution)

## Recalls

- Z-1045-2025 · Class II · ongoing · initiated 2025-01-28: The user can continue to take the next exposure after reaching the Automatic Exposure Control (AEC) limit, without taking any further actions to acknowledge or adjust exposure techniques. In all cases, a message still appears on the screen when the AEC limit is reached.
- Z-0552-2024 · Class II · ongoing · initiated 2023-11-07: GE HealthCare has become aware of the potential that incorrect torque has been applied to certain bolts of the Definium Tempo and Definium Tempo Pro products which may result in a potential fall of elements of the Overhead Tube Suspension (OTS) assembly.
- Z-0553-2024 · Class II · ongoing · initiated 2023-11-07: GE HealthCare has become aware of the potential that incorrect torque has been applied to certain bolts of the Definium Tempo and Definium Tempo Pro products which may result in a potential fall of elements of the Overhead Tube Suspension (OTS) assembly.

## Identity

- Trade name: Definium Tempo Pro [EUDAMED]; Definium [FDA GUDID (AccessGUDID)]
- Generic name: Stationary basic diagnostic x-ray system, digital [FDA GUDID (AccessGUDID)]
- Device name: Medical Diagnostic Radiology Device [EUDAMED]
- Model / Ref / Catalog: Definium Tempo Pro [EUDAMED]; B2402CAB [EUDAMED, FDA GUDID (AccessGUDID)]; Tempo Pro [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 00195278070265 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 8406821BUG00193HJ [EUDAMED]
- FDA product code: MQB [FDA GUDID (AccessGUDID)]; IZF [FDA GUDID (AccessGUDID)]; KPR [FDA GUDID (AccessGUDID)]
- EMDN code: Z11031101 [EUDAMED]
- GMDN term: Stationary basic diagnostic x-ray system, digital (37645) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class IIb [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 892.1680 [FDA GUDID (AccessGUDID)]; 892.1740 [FDA GUDID (AccessGUDID)]
- System or procedure pack: System which is a device in itself [EUDAMED]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: France [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Serial number: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Lot / batch number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Definium Tempo Pro, GE HUALUN MEDICAL SYSTEMS CO. Ltd. deviCERTS medical device catalogue. https://devicerts.com/devices/definium-tempo-pro-b2402cab (data as of 2026-11-26).
- Data sources: [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-24
- Statuses computed as of: 2026-11-26
- JSON: <https://devicerts.com/devices/definium-tempo-pro-b2402cab.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/definium-tempo-pro-b2402cab
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.
