Skip to content

Dermalon 88861741-11

by Covidien LP

Dermalon 88861741-11 is a nylon suture (FDA Class II; FDA product code GAR, Suture, Nonabsorbable, Synthetic, Polyamide) made by Covidien LP, cleared under FDA 510(k) K981582 on 13 Jul 1998 and listed in FDA GUDID since 30 Aug 2015 (UDI-DI 10884521070691), active as of 23 Oct 2026. 4 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

4 ongoing

This device is named in the recall

Documents

510(k) K981582

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10884521070691 UDI-DI Date30 Aug 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK981582 Date13 Jul 1998DecidedStatusActive

Official records

From the FDA record

Device description
Monofilament Nylon
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K981582 decided 13 Jul 1998 Active
  • FDA GUDID UDI-DI 10884521070691 listed 30 Aug 2015 Listed

Recalls

9 recalls · 4 ongoing · FDA

    • Ongoing Z-2920-2026 FDA Class II initiated 24 Jun 2026

    Product may contain a perforation or tear in the sterile barrier packaging. This issue may result in biocontamination of the sterile sutures, which may lead to infection, loss of vision if in ophthalmic utilization, or prolonged surgery.

    • Ongoing Z-0844-2024 FDA Class II initiated 21 Dec 2023

    Specific lots of sutures were sterilized with gamma doses that exceeded the range approved. The extra gamma levels may decrease the strength of the sutures over time, which could result in harms such as wound dehiscence and hemorrhage/blood loss/ bleeding at a critical level.

  • 2 recalls, same reason

    • Ongoing Z-1172-2023 FDA Class II initiated 2 Dec 2022
    • Ongoing Z-1178-2023 FDA Class II initiated 2 Dec 2022

    Sterile Barrier Breach of Breather Pouch may cause infection or vision loss for ophthalmic procedures in cases where there is direct patient contact

  • 5 recalls, same reason

    • Terminated Z-2821-2011 FDA Unclassified (pre-2012) initiated 3 Jun 2011 on shared 510(k) K981582
    • Terminated Z-2823-2011 FDA Unclassified (pre-2012) initiated 3 Jun 2011 on shared 510(k) K981582
    • Terminated Z-2820-2011 FDA Unclassified (pre-2012) initiated 3 Jun 2011 on shared 510(k) K981582
    • Terminated Z-2822-2011 FDA Unclassified (pre-2012) initiated 3 Jun 2011 on shared 510(k) K981582
    • Terminated Z-2824-2011 FDA Unclassified (pre-2012) initiated 3 Jun 2011 on shared 510(k) K981582

    Potential for the sterile barrier to be breached compromising the sterility of the product

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

11 dated events

  1. Recall initiated FDA recalls Z-2821-2011
  2. Recall initiated FDA recalls Z-2823-2011
  3. Recall initiated FDA recalls Z-2820-2011
  4. Recall initiated FDA recalls Z-2822-2011
  5. Recall initiated FDA recalls Z-2824-2011
  6. Listed FDA GUDID 10884521070691
  7. Recall initiated FDA recalls Z-1172-2023
  8. Recall initiated FDA recalls Z-1178-2023
  9. Recall initiated FDA recalls Z-0844-2024
  10. Recall initiated FDA recalls Z-2920-2026

1 earlier event are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Dermalon
Generic name
Nylon suture, non-bioabsorbable, monofilament
Model / reference
88861741-11
Primary DI / UDI-DI
10884521070691
510(k) Number
FDA product code
GAR
GMDN term
Nylon suture, non-bioabsorbable, monofilament
Device class
Class II
Regulation number
878.5020
GUDID distribution status
In Commercial Distribution
Size
Length — 18 Inch

Similar devices in this category

Other devices filed under Nylon suture, non-bioabsorbable, monofilament.

Other devices from Covidien LP

  • Invos PM7100

    Class II
  • Invos PMAC71DOC Open recall

    Class II
  • LigaSure MRASILF19

    Class II
  • Shiley 110860

    Class II

See all devices from Covidien LP →

Properties

  • Supplied sterile
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (9, all answered No)