Digital Dental Image Scanner

by Jiangsu Dynamic Medical Technology Co., Ltd 510(k)

Active United States

510(k) K231660

Regulatory status

as of 29 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK231660 Date20 Dec 2023ClearedStatusActive

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Recalls

0 recalls · FDA

No FDA recalls on record, checked 22 Oct 2026.

Specification

510(k)

Full name
Digital image scanner of dental
510(k) Number
FDA Product Code
MUH
FDA applicant
Jiangsu Dynamic Medical Technology Co., Ltd.
Device Class
Class II
Regulation
21 CFR Part 872.1800
Advisory Committee
Dental
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is a Digital Image Scanner of Dental, classified as an extraoral X-ray system with a digital receptor. It captures high-resolution radiographic images of dental structures for diagnostic and treatment planning purposes, replacing traditional film-based methods with digital imaging technology.

The scanner is intended for use in dental clinics and oral healthcare settings. It is supplied as a reusable medical device, with no indication of sterility requirements in the provided data. The device operates within Class II regulatory classification under FDA 510(k) clearance (K231660) and adheres to regulatory number 872.1800. Multiple model variants are referenced, including registration numbers such as 3000190675 and others, but specific sizes or MRI safety information are not detailed in the data.

Other devices from Jiangsu Dynamic Medical Technology Co., Ltd

See all devices from Jiangsu Dynamic Medical Technology Co., Ltd →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • Is this dental image scanner designed for single-use or can it be reused in a clinical setting?

    This device is explicitly described as a reusable medical device. Since it is classified as an extraoral X-ray system with a digital receptor, it is intended for repeated use in dental clinics and oral healthcare settings, though standard decontamination and maintenance procedures must be followed to ensure safety and functionality.

  • What types of dental images can this scanner capture, and how does it differ from traditional film-based methods?

    This scanner captures high-resolution radiographic images of dental structures, including extraoral views, replacing traditional film-based methods. Unlike film, it uses digital imaging technology, allowing for immediate viewing, storage, and sharing of images—eliminating the need for chemical processing and reducing patient exposure to radiation during retakes.

  • Are there multiple models available, and if so, how can I identify the correct registration number for my needs?

    Yes, multiple model variants exist, each with its own registration number (e.g., 3000190675, 3038718579, etc.). These numbers are tied to specific submissions under the FDA 510(k) clearance (K231660) and regulatory product code MUH. To identify the correct model, consult the manufacturer’s documentation or contact Jiangsu Dynamic Medical Technology Co., Ltd. directly, as the provided data does not specify size or variant distinctions.

  • Does this device require sterilization before use, and if not, what cleaning procedures should be followed?

    The provided data does not explicitly state sterilization requirements, but since it is reusable, standard decontamination protocols (e.g., cleaning with approved disinfectants) must be followed to prevent cross-contamination. Always refer to the manufacturer’s instructions for use (IFU) for specific cleaning guidelines, as improper handling could affect performance or regulatory compliance.

  • How is this device regulated, and what does the FDA’s classification mean for dental professionals?

    This device falls under FDA Class II regulatory classification and was cleared via a Traditional 510(k) pathway (K231660) with a Substantially Equivalent (SESE) determination. The Dental advisory committee (DE) reviewed it, and it adheres to product code MUH and regulation 872.1800. For dental professionals, this means it meets FDA standards for safety and effectiveness as an extraoral X-ray system, though compliance with local facility protocols and radiation safety guidelines remains mandatory.