Dimension® DOA-Negative Control 10445032
by Siemens Healthcare Diagnostics Inc.
Ref 10445032Model IVDR_67_GLA_DUB-C_B_REAG_DOA Negative Control
Dimension DOA-Negative Control 10445032 (DC44A) is a multiple drugs of abuse IVD (EU IVDR Class B; FDA Class I; FDA product code DIF, Drug Mixture Control Materials) made by Siemens Healthcare Diagnostics Inc., registered in EUDAMED on 23 Jul 2026 (Basic UDI-DI 0405686901095VF) and listed in FDA GUDID since 24 Sep 2020 (UDI-DI 00842768005145), active as of 25 Oct 2026.
Active
CE IVDR
Valid until
No date given
FDA recalls
Not checked
Documents
None linked in EUDAMED
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/IVDR EUDAMED | Number0405686901095VF 00842768005145 | Date23 Jul 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00842768005145 | Date24 Sep 2020 | StatusListed |
Official records
- EUDAMED public site 0405686901095VF
- AccessGUDID record 00842768005145
From the FDA record
- Device description
- Drugs of Abuse Negative Control, 6x5mL
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 0405686901095VF registered 23 Jul 2026 Active
- FDA GUDID UDI-DI 00842768005145 listed 24 Sep 2020 Listed
Timeline
- Listed FDA GUDID 00842768005145
- Registered EUDAMED 0405686901095VF
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Dimension Drugs of Abuse Negative Control EUDAMEDDimension® DOA-Negative Control GUDID
- Generic name
- Multiple drugs of abuse IVD, control
- Device name
- IVDR_67_GLA_DUB-C_B_REAG_DOA Negative Control
- Model / Ref / Catalog
- 10445032, IVDR_67_GLA_DUB-C_B_REAG_DOA Negative Control, DC44A
- Primary DI / UDI-DI
- 00842768005145
- Basic UDI-DI
- 0405686901095VF
- Unit of use DI
- 00630414004624
- FDA product code
- DIF
- EMDN code
- W0102152009 Controls for narcotics / toxicology
- GMDN term
- Multiple drugs of abuse IVD, control
- Device class
- Class B EUDAMEDClass I GUDID
- Regulation number
- 862.3280
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class B | Class I |
Similar devices in this category
Other devices filed under CONTROLS FOR NARCOTICS / TOXICOLOGY.
- ARK Pregabalin II Control 5059-0003-00 by ARK Diagnostics, Inc.
- Immunalysis 3001-15 by Immunalysis Corporation
- ARK Methylphenidate Metabolite Control 5042-0003-00 by ARK Diagnostics, Inc.
- Synchron 474991 by Beckman Coulter, Inc.
- Immunalysis 3005-5 by Immunalysis Corporation
- Triage 94614 by Quidel Cardiovascular Inc.
- MGC Primary DAU Control Set 100200 by Microgenics Corporation
- Triage 94613 by Quidel Cardiovascular Inc.
- Fentanyl Control Set 10426667190 by Lin-Zhi International, Inc.
- MGC Select DAU Control Set 100202 by Microgenics Corporation