Skip to content

Dimension® T4 Calibrator 10445029

by Siemens Healthcare Diagnostics Inc.

Ref 10445029Model DX LS_LEGACY_00842768004919

Dimension T4 Calibrator 10445029 (DC13) is an in vitro diagnostic device (EU IVDD general IVD; FDA Class II) made by Siemens Healthcare Diagnostics Inc., registered in EUDAMED on 5 Oct 2026 (Basic UDI-DI B-00842768004919), cleared under FDA 510(k) K862359 on 19 Aug 1986 and listed in FDA GUDID since 24 Sep 2016 (UDI-DI 00842768004919), active as of 24 Oct 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE IVDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

2 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K862359

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/IVDD EUDAMED NumberB-00842768004919 Basic UDI-DI 00842768004919UDI-DIDate5 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00842768004919 UDI-DI Date24 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK862359 Date19 Aug 1986DecidedStatusActive

Official records

From the FDA record

Device description
Thyroxine Calibrator, 2x5x1mL, reconstituted
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
Labelled as containing natural rubber latex
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 24 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00842768004919 registered 5 Oct 2026 Active
  • FDA 510(k) K862359 decided 19 Aug 1986 Active
  • FDA GUDID UDI-DI 00842768004919 listed 24 Sep 2016 Listed

Recalls

2 recalls · FDA

    • Terminated Z-1654-2018 FDA Class II initiated 29 Jun 2017

    Various assays used to measure different chemical levels in blood, urine, or cerebrospinal fluid may interfere with the drugs sulfasalazine and/or sulfapyridine causing falsely elevated or falsely depressed results.

    • Terminated Z-1662-2016 FDA Class II initiated 17 Mar 2016 on shared 510(k) K862359

    Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyrone) interference with Trinder and Trinder-like reaction assays. Siemens has confirmed that falsely depressed results may occur on samples drawn from patients receiving N-Acetylcysteine (NAC) or Metamizole. NAC is the accepted antidote for acetaminophen toxicity and is justified in patients at signific

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

5 dated events

  1. Cleared FDA 510(k) K862359
  2. Recall initiated FDA recalls Z-1662-2016
  3. Listed FDA GUDID 00842768004919
  4. Recall initiated FDA recalls Z-1654-2018
  5. Registered EUDAMED B-00842768004919

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Dimension Thyroxine Calibrator EUDAMED
Dimension® T4 Calibrator GUDID
Generic name
Total thyroxine (TT4) IVD, calibrator
Device name
Dx LS_LEGACY_00842768004919
Model / Ref / Catalog
10445029, DX LS_LEGACY_00842768004919, DC13
Primary DI / UDI-DI
00842768004919
Basic UDI-DI
B-00842768004919
510(k) Number
FDA product code
CIG, JIT
EMDN code
W0101050302 Calibrators single component (cc)
GMDN term
Total thyroxine (TT4) IVD, calibrator
Device class
Class IVD General EUDAMED
Class II GUDID
Regulation number
862.1110, 862.1150
EU registration type
Legacy device (under a directive)
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IVD General
GUDID
Class II

Device class is stated on each registry's own scale: Class IVD General in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under CALIBRATORS SINGLE COMPONENT (CC).

Other devices from Siemens Healthcare Diagnostics Inc.

See all devices from Siemens Healthcare Diagnostics Inc. →

Properties

  • Contains latex
  • Contains human tissues or cells
  • Contains animal tissues or cells
  • Contains substances of microbial origin
  • Reagent
  • Professional testing
  • Lot / batch number
  • Expiration date
Other properties (18, all answered No)